Philippines - Procurement of Various Hospital Equipment for the use of Godofredo P. Ramos Hospital, Altavas, Aklan/ITB no: 2018-849

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
22 November 2018
Opportunity publication date
14 November 2018
Value of contract
to be confirmed
Your guide to exporting
Report opportunity

Description

1. 8 unit Hospital Bed & Complete Accessories w/ Mattress , Side Rail & IV Pole Dimensions : L 2160mm x W 1000mm x H 520mm Bask-Rest section Lifting Angle: 80Degrees Knee-rest/Leg section Lifting Angle : 4 Low Position Lift: 520mm Accessories: IV Pole, mattress, over Bed, Foot stool & Bedside Table Bed Side: 450mm x 470mmx755mm 1 drawer & 1 Storage cabinet ( 2 layer shelves) Hidden pull-out tray for cups & article: w/4 caster wheel 2. 8 unit Oxygen Regulator Specification: Supply Pressure : 500-2200psi Outlet Pressure: High flow outlets: 40-60 psi at 500-2200 psi inlet pressure Filter: 25micron intered bronze Safety relief Pressure: 75-125psi Operating Temperature: -30Degrees F to 125DegreesF Storage Temperature: -20Degrees F to 120Degrees F Stainless steel, Vitron, Silicon, & Teflon 3. 4 unit Thermometer ( Infrared) Ambient Operating Temp. Condition: 32 to 122F (0 to 50C) Dimensions: 6x1.5 x 3in Display Type: Backlight LCD Emissivity: Preset at .97 for higher accuracy for blood safety application Field of View: 12 to 1 Included Accessories: 2AAA Batteries Temp Accuracy: +/-1F from 32 to 150F Temp. Range: -67 to 536F)-55 to 280C) Unit Weight: 1 lb 4. 2 unit
Sphygmomanometer w/ stand and basket Non Mercurial w/cuff and stethoscope 5. 1 unit
ECG Machine 3 channel DESCRIPTION 3.5inch TFT Screen 12 leads simultaneous display Thermal printing system Power supply both AC and DC High capacity built-in lithium rechargeable battery Battery power supports continually record 150 pieces of ECG Build-in database Store more than 1000 pieces of archive Digital signal processor for filter Auto-measurement, auto-analysis and auto interpretation functions Lead: Standard 12 leads Patient leak current: Less than 10uA Input impedance: Greater than or Equal to 50MegaOHM, Frequency response: 0.05Hz-150Hz (-3dB) Time Constant: >3.2 seconds CMRR: 100dB Dimension of recording paper 80mm(w) X 20m(L)paper Paper Speed: 25mm/s, 50mm/s Paper sizeZ: 80mm x 20mm Sensitivity choice: 5,10,20mm/mV. Standard is 10mm/mV+0.2mm/mV Measurement parameters: HR,P-R interval, P-Duration , QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) Product safety type: Class 1 Type CF, there is defibrillation and pacing protection circuit Enduring polarization voltage :+ 300mV Noise level: :Less than or equal to 15uVp-p Size: 315mm(L) X 215mm(W) X 77mm(H) Net Weight: 2.25KG 6. 1 unit
Weighing Scale W/ Height & Weight Superior Accuracy Heavy Duty under structure Die cast beam, and aluminum on black Easily read from either side Factory Assembled Capacity: 400lb s x 402 (180kg. X 100g) Platform Size: 10x12x14x ½ inch Scale Height: 59inch (1.5m) 7. 2 unit
Pulmo Aide Nebulizer Heavy Duty Size; 10.1inchWx10.5inch Hx6.5inchD Weight: 7lbs Power Req. 1.3Amp, 115VAC 60Hz Power somsumption: 90W Max Comp. Pressure: 30psig or greater Free Airflow: (1pm) 9 1pm or greater Neb. Operating Pressure: 12-18 psi Sound level: 51 dBA Compressor Type: Diaphragm 8. 1 unit
Ampule Opener Housing Made of light gray plastic Ampule Waste Removable Measurement: 90x150x200mm Spring loaded diamond file fixed on rust on rust free plate