Poland - Medical supplies
For more information and to make a bid you will need to go to the third party website.
Details
Provided by
- Opportunity closing date
- 18 December 2020
- Opportunity publication date
- 17 November 2020
- Category
- 33140000
- Value of contract
- to be confirmed
- Your guide to exporting
Description
Task 1 - generator respiratory systemTask 2 - Inflant accessories FlowTask 3 neonatal central cannulaTask 4 - Troacar catheter 8-30 FrTask 5 - SpO2 sensors for NIHON KOHDEN and Hawlett PackardTask 6 - isolating lids for neonatal skin temperature sensorsTask 7 - chest drain kitTask 8 - phototherapy glasses for newborn babiesTask 9 - high and low flow nasal cannulasTask 10 - intubation tube stabilizer size from mini to macro op.= Task 11- exchangeable transfusion kit Task 12- straps to transport incubator Task 13 - SLE-type ventilator breathing system 2000 Task 14 Single-use breathing system for transport ventilator Medumat Standard 2 Task 15 - Arctic Sun 5000 single-use pad compatible with Arctic Sun 5000 Task 16 Needle pads for aEEG Task 17 - Neonatal breathing system
Neonatal respiratory system with disposable generatorMicrobiologically cleanAdapted to Fischer&PaykelHumidifiers Single packedExpiration date and series number on the individual packageStep description on the individual package in PolishSystem composition:- Inspiratory section heated 1.2 m long, internal diameter 10 mm- non-heated exhalation section with occlusion protection holes, along the entire length of the section- a section connecting the humidifier with the ventilator- a set of 3 nasal tips of size: S, M, L-generator IF with elastic soft attachment straps, - generator cradle for attaching the generator to the cap, made of elastic T-shaped plastic, with Velcro fastening - clips - 4 piecesSamples of 1 piece to test and check compliance with the above description. The respiratory system will be tested on the basis of the following assumptions - stability of connections - flexibility Microbiologically pureCompatible with Inflant FlowPackaged individuallyExpiration date and series number on the individual packageS nasal mask in S,M,L,XLC Cap in "00", "0", "1", "1", "2", "3", "4" Description on the individual package in PolishSamples in 1 pc. (1 piece each of 1,2,3) in order to test and check compliance with the above description. The samples after the testing will be handed over for disposalQuality conditions subject to evaluationAccessories will be tested on the basis of the following assumptions - no irritation and allergic reactions - matched to the anatomical shape Sterile Original manufacturer's packaging guaranteeing sterility for a period of 12 months from the delivery dateExpiration date and series number on the individual packagingDescription on the individual packaging in PolishSamples in the amount of 1 piece from each item from 1-11 in order to test and check compliance with the above description. After testing, they will be sent for disposalPoz.1- Neonatal and infant catheter inserted peripherally for chronic venous accessManufactured from thermosensitive polyurethaneSize 2FR (0.2x0.6mm), 15 or 30cm long with an integral 14cm extension tube made of PURO marking on the catheter every 1cmAdditional marker every 5cmCatheter inserted through a breakable needle or an entertaining cannula.The catheter for neonates and children will be tested based on the following assumptions:- possibility to control the catheter placement in the vessel using the X-ray and ultrasound equipment - no complications and reactions after catheter placementPoz.2- Percutaneous micro catheter inserted peripherally for chronic useCatheter terminated with flexible wingsManufactured from thermosensitive polyurethaneSize 1FR (0.15x0.3mm)Marking every 1 cmEmbedded catheter lumen bending protectionCatheter inserted with an entertaining needle or cannulaIn the set composition:- Sterile tape to be measuredLengths required 8, 10, 15, 20,30 cm - to be selected by the ordering partyPossible to select the length by the ordering partyPossible to select a kit with or without metal guide Conditions to be evaluatedCheck the position of the catheter in the vessel with an X-ray and ultrasound deviceCatheter inserted with a G-24 amusement needle or G 24 cannula or a Microflesh (peel away) 20G- to be selected by the ordering partyPoz.3 - Pediatric catheterCatheter made of PURCatheter 4.6.8.20 cm longCatheter 0.5 mm - 0.7 mm in diameter With wings for fixing in the set composition:- 0.5-0.8 mm diameter puncture needle - straight guide with a flexible tip depending on the length of the catheterCannula inserted using the Seldinger methodPossibility to choose the length and diameter by the ordering partyConditions to be evaluatedCanontrol the position of the catheter in the vessel by means of X-ray and ultrasound sterilePackaged individuallyOriginal manufacturer's packaging guaranteeing sterility for a period of 12 monthsExpiration date and batch number on the individual packagingSamples in the amount of 1 pc. From each item in order to test and check compliance with the above description. After testing, the troacar catheters will be sent for disposalPoz.1,2,3TroacarCatheter for pleural drainageCatheter made of soft transparent plasticPoz.1 - neonatological, size 8Fr and 10 Fr 8 cm long, with contrasting rings, scaled every 1 cm, distal tip with side opening, proximal tip with luer-lock, metal troacar with sharpened tipPoz.2 - 25 cm long, markers every 2 cm from 2 to 14 cmPoz.3 - 28 cm long, markers at 5, 10 and 15 cm from the end, equipped with a fastening collarTwo side eyelets - item 2. item 3X-ray contrast thread Conditions to be evaluatedThe handle provides good control when making a puncturePoz.4,5-Drainage valve type Heimlich- transport two-chamber and luer-end connector - Heimlich valve lockDual-chamber polyurethane transparent system with vent -poz1Distant and proximal funnel-end connector -poz1Latex catheter -poz1Ability to apply suction by manually pressing the compartment marked with an arrow (suction approx. 150 mbar) -poz. 4 Connector with luer end - Heimlich valve lock -poz.5The male end and the other side of the connector ends in a soft draught -poz. 5 Conditions to be assessedFitness of the Heimlich valve connection with pleural drainage catheter Pos.1.2 SpO2 sensors for NIHON KOHDEN and Hawlett Packard1 Sterile2 Single packed3 Expiration date and series number on the individual pack4 Description on the individual pack in Polish5 Hypoallergenic6 Compatible with Nihon Kohden patient monitor pos.17 Compatible with Hawlett Packard8 Gentle, non-irritating baby skin9 Resistant to frequent change of sensor attachment8 Samples of 1 from each position to test and check compliance with the above description. After testing, the samples will be passed on for disposal Conditions to be evaluated1 Matched to the anatomical shape Yes-20 no-02 No allergic reactions and skin irritations Yes-20 no-0 Self-adhesive Single useMessage up to 2.5 cmSamples covered with a reflective layerAdrifiable adhesive surface covered with a gentle adhesive that does not cause skin irritationExpiration date and batch number on the individual packageSamples in 1 item per item to test and verify compliance with the above description. After testing, the samples will be transferred to the disposal of Sterile gravitational and active drainage Sterile single-packed Expiry date and series number on the individual packageDescription on the individual package in PolishDescription on the individual package in PolishDescribed 1000 ml secretion chamber with a drain valve (possibility of multiple emptying of the secretion chamber) pos. 1Discussed 400ml collection chamber with drain valve (possibility of multiple emptying of the collection chamber) pos. 2D additional precise graduation for small volumes pos. 1Additional precise graduation for small volumes (in the range up to 10 ml every 2 ml, in the range 10 - 50 ml every 5 ml) pos. 2Low-resistance one-way Scheffler's valve with a swinging valveParthenware to inform about the state of expansion of the lung and enable additional evacuation of liquid and airSmooth mechanical adjustment of the suction force by means of a knob in the range from 0 to 45 cm H20 with an additional indicator of the actual suction forceAutomatic safety valves for positive and negative pressurePortacle and scale of the pleural leakagePortacleless port to take a 1-piece sample of the secretionSamples from each position to test and verify compliance with the above description. After testing, the specimens will be handed over for disposalQuality conditions to be assessedConnection stability with drainage kitManufactured from non-irritating materialManufactured from stretchable material with an adjustable (Velcro fastening)Y-shaped to fit any head shapeThe latex-free materialFor newborns with a head circumference of 20 -38 cmSamples of 1 piece to test and verify compliance with the above description. After testing, they will be sent for disposalBiologically cleanPackaged individuallyCan be used with low or high oxygen flowMay be used with moisturizerSoft, curved frame for connection to the respiratory system of the ventilator, CPR to maintain continuous positive airway pressureIn 15 mm adapter kit for connecting the oxygen drainSilicone o-ring for cannula supportColour size designation on the ringColour size designation on the ring Doesn't include latex, natural rubber, DEHPRPRATAN ftlane-dependent measurements available from Micro Premie to Large for the newborn baby to choose fromSamples of 1 piece. to test and check compliance with the above description. After testing, the samples will be sent for disposalConditions to be evaluated - anatomically fit - no complications and allergic reactionsBeaten-pure Biologically cleanSingle packaging op. = 5 pcsSizes marked with different coloursSize of choiceFitted with hydrocolloid patchesFor use in patients from 600g to over 2000gFree of harmful phthalates DEHPB without latexSamples of 1 pc to test and verify compliance with the above description. After testing, the samples will be handed over for disposal SterileDate of expiry date and series number on the individual package valid 12 months from the date of deliveryDescription on the individual package in PolishSet composition:1 four-way faucet with a latex connector for the administration of drugs1 a drain tube for the removed blood1 5Fr (PVC XRO)1 7Fr (PVC XRO)2 Luer syringe - Lock 20 ml1 Luer syringe - Lock 10 ml1 Luer 15 x 0 hypodermic needle,5 mm (25G)1 blood collection container1 blood transfusion kit1 15 cm long line for measuring venous pressure3 cotton swabs 50 x 50 mm1 50 x 60 cm napkin with hole1 pair of gloves1 control card1 vent needleSamples 1 pc. to test and check compliance with the above description. Samples after testing will be sent for disposal Supporting belts Packed in 10 pcs. eachDescription on the individual package in Polish for single useCompatible with the Globe-Trotter GT 5400 IncubatorSamples in 1 piece to test and check compliance with the above description. After testing, the samples will be transferred for disposal Sterile or microbiologically purePacked individuallyExpiration date and batch number on the individual packageInhalation label on the individual package in Polish:- 0.8 m corrugated tube with flexible self-adjusting connector 9-11 mm on the ventilator side and 22F on the humidifier side - automatically filling chamber with integrated water intake pipe equipped with a punch - corrugated tube with 22F end on the humidifier side, with a 7.6 mm port equipped with a heating coil - Y-connector with a 7.6 mm port with a 15F patient end and an integrated monitoring line - flow limiter placed between the Y-connector and the inspiratory expiratory branch:- 1.6 m corrugated tube with 15M end on the ventilator side with self-adapting neonatal water trap and 7.6 mm port - additionally a set of straight connectors and elastomer endings, as well as connectors for nitrogen oxide feeding and samplingThe heater input on the inspiratory line with a triangular notch for connecting the temperature sensor also used for the Fisher & Pykel MR 850 humidifier. The system is designed to operate the ventilator at an air flow of >4l/min. Samples to be tested in 1 piece to check compliance with the above description. The samples will be sent for disposal after testing. 200 cmStep volume max. 21 ml ration 1.Volume of dead space max. 14 ml ration 2.Samples to be tested 1 piece per job to check compliance with the above description... After testing, the samples will be sent for disposal. Disposable pad compatible with Arctic Sun 5000 size S device, transferring thermal energy. Used for therapeutic hypothermia of the patient. Three-layer construction of the pads (hydrozel insulation layer0 to minimize the loss of heat to the environment, provide rapid cooling and control depending on the duration of therapyThe pad(s) for newborn infants to the patient's temperature management system in the range 32-38.5 oC; Arctic Gel disposable mattress. Size of choice for aEEG needle electrodes model CFM for single and double channel (10 black, 10 red, 10 yellow) EEG electrodes through skin, disposable, bio-pure neonatal respiratory system with interchangeable nCPAP/HfOT, disposable (microbiologically pure) with silver ion based antimicrobial protection adapted to the removable therapy capW kit included:- heated inhalation section 1.2 m long, ΓΈ inside10mm, length to incubator length 0.3m- connection section between humidifier and ventilator length 0.6m - 2.1 m long pressure measuring section, - with nCPAP connector, - nasal cannula connectorAccessible for high-flow therapy, with safety valve, connector for flowmeter, - with nCPAP connector. 10 cmNose cannula in available sizes: - premature infant, 1-8L-neonatal, 1-8 L- infant, 1-10L- large infant, 1-25 L- pediatric, 1-25 L- skin temperature sensor for newborns to ATM Dual Incu hybrid incubator
- Opportunity closing date
- 18 December 2020
- Value of contract
- to be confirmed
About the buyer
- Address
- Uniwersytecki Szpital Kliniczny w Opolu al. W. Witosa 26 Opole 45-401 Poland
- Contact
- kamil.flak@usk.opole.pl
The deadline to apply for this opportunity has passed.
Visit the
opportunities page
to find another.