Poland - Medical materials

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
12 July 2019
Opportunity publication date
10 June 2019
Category
33140000
Value of contract
to be confirmed
Your guide to exporting
Report opportunity

Description

1 Sterile foam dressing set for vacuum therapy in sizes 10x8x3 cm, 20x12.5x3 cm, 25x15x3 cmSet composition: - sterile foam dressing, - soft elastic port with a drain lined with sponge that minimizes pressure, filled with additional material preventing clogging and bending of the drain during therapy. The drain ends on one side with a canister-compatible quick connector, - occlusal self-adhesive foil. 3002 Y-Switch allowing to connect two sterile ports with one vacuum device pcs. 103 Canister - disposable canister with exudate gelling agent: - with transparent tube ended filter for connection to vacuum wound treatment device, - with additional tube ended on one side with quick connector and on the other end for connection to canister, - canister sizes: 800 ml, 250 ml, 750 mlSht. 3004 Single-packed drains with soft padded duct to prevent clogging during use and the formation of bedsores pcs. 2505 Occlusal self-adhesive foil in various sizes pcs. 100 For the duration of the contract, the Ordering Party requires the free lending of a device for vacuum wound treatment therapy (minimum 5 devices): - portable - optional attachment of a portable bag,- pressure range 40-200 mmHg,- battery charging time - 3 hours, approx. 80 % capacity, - battery life - about 20 hours, - operating cycles - continuous or alternating, - digital display, - automatic lock - blocking after 10 minutes, - gel powder that causes clotting in the canister, - markings on the tank, - antibacterial filter inside the canister, - low battery alarm, - low pressure alarm, - high pressure alarm, - full canister alarm, - cable blocking alarm, - hose clamps, - alarm not working device, - power supply option 1. Disposable operating apron of SPUNLACE type. Sterile. Made of SMS unwoven fabric with min. weight. 35g/m2. Provides reliable protection against bacteria and liquids. Guarantees air, heat and steam circulation. For comfortable wearing. Breathable - pleasant for the skin. Complex in a way that ensures "sterile back" - with wide overlapping overlaps, straps placed in a cardboard box that allow them to be tied aseptically. On the outer packaging, at least a double set of labels for medical documentation with barcode, catalogue number, expiry date and serial number. Visible size designation on the packaging meeting the requirements of European Standard EN13795. Sizes M, L, XL, XXL Length 130 cm, 150 cm, 170 cm (+- 5 cm). Could be with two towels. 12000 1. drill bits for high-speed drill compatible with your existing drill in the operating block. For contra-angle handpieces and straighteners:- diamond with a diameter of 2.5mm - 7.5mm long 14cm - coarse diamond with a diameter of 3.0mm long 14cm - steel roses with a diameter of 2.0-9.0mm long 14cmSht. 1402 Drill bits for high-speed drill compatible with the existing drill in the operating theatre. Steel drills for cranitome, straight and spiral, diameter 2.3mm, length 8cm, length 8cm. 1003 Disposable trepan for perfarotara compatible with your drilling machine External diameter 14mm, internal diameter 11mm, rim 3mm pcs. 1 1 Sterile single-use sterile neurosurgical suction pump, bent angle 150 with plastic handle, green marking, suction power adjustment - hole 1,5 mm, working part length 130 mm, diameter 6 CH/2 mm outside, diameter 1,45 mm mast. 1202 Sterile single-use sterile steel neurosurgical suction pump, bent angle 150 with plastic handle, blue marking, suction power adjustment - hole 1,5 mm, working part length 130 mm, diameter 9 CH/3 mm ext., inner diameter 2,54 mm, pcs. Disposable sterile steel neurosurgical suction pump, bent angle 150 with plastic handle, white marking, suction power adjustment - hole 1,5 mm, working part length 130 mm, diameter 12 CH/4 mm outside, inner diameter 3,0 mm, pcs. 120 1 Line stacker disposable handle with knife integrated in the load and sequential staple height adjustment - individually packaged, compatible load for standard tissue (1.5 mm closed), intermediate tissue (1.8 mm closed) and 2 mm thick closed). It has 6 rows of staples made in 3D spatial technology with a seam line length of 81 mm. 802 Universal load for disposable line stacker with knife with sequential height adjustment of staples for standard tissue (1.5 mm after closure), intermediate tissue (1.8 mm after closure) and thicker 2 mm after closure. It has 6 rows of staples made in 3D technology of seam line length 81 mm (knife integrated with the load). 200 1 Balloon ureter expanderSpecial holder with stick vice included in the set is designed to stabilize the guide during insertion. 5FR/65cmBalloon 5mm/4cm 62. Open-ended urethra catheter Flexible, open-ended tip is designed for atraumatic insertion into and passage through the urethra and allows placement on a guide. (pack 10pcs) 6FR/70cm 43. Open-ended ureter catheterApplied for retrograde heliogram, drainage and control in the ileum ureter. (pack 10pcs) 7FR/70cm 24. Laser ureter cathetersApplied to the protection and administration of laser fiber in the ureter. 3Fr/115cm 45. occlusal balloon catheter for pelvic ureter connection Used to temporarily block the pelvic ureter connection to prevent stone fragments from entering the ureter during the percutaneous lithotripsy procedure and to inject the shading agent. 6FR/75cm 66. Endoscope stopperSupports to maintain tightness around the devices or guides inserted by the endoscope. .025'-.038' 1007. Areteroscopic irrigation system Used for controlled manual irrigation during endoscopy. single-use two-part trocar needleApplied for access to percutaneous nephrostomy. 18G/20cm 109. Needle to incise the fascia, inserted after the guide to the incision of the renal fascia in order to facilitate the widening of the musculoskeletal canal. 18G/5cmCutting edge 10mm 410. Amplatz guide plate is made of stainless steel, straight, with a flexible tip, and is used to create a channel and facilitate the positioning of surgical devices. .038"/145cm 4011. Two-channel urethral access catheter Used to inject contrast agent and anesthetic gel and/or to insert a protective guide. 6/10FR/50cm 212Nitinol core guideDouble-function guide with flexible tips at each end, one straight and one angled, suitable for use at each end. Benefit by reducing the number of tools you need. 035"/150cm 213. Spiral deposit extractorServe to manoeuvre the deposits and remove them from the urinary tract. 2.8FR/115cmKoszyk 4 wires 414. 3.2FR/115cmKoszyk 4 wires 415. 12FR/35cm ureter access shirt 616. 12FR/55cm ureter access shirt 617. 1.7FR/115cmKoszyk 1cm4/16 wires 1018. Stent extractor 1.7FR/115cm 1019, Stent extractor 4.5FR/65cm 220, Umbrella-shaped 2.8FR/145cm Cage 7mm 2021, Nitinol, Endless Cage extractor 1.5FR/115cm Cage 1cm 1022. Guide wire used to locate and replace a catheter in a twisted or looped ureter or to conquer large stones on the way to the kidney. 6FR/24cm 224 metal ureter stent set. 035"/145cm 425 flexible tip on both sides. 6FR/26cm 4026 soft ureter stent set. Set of soft ureter stent 7FR/28cm 20W due to restrictions in standard forms used for publication of announcements in the Official Journal of the European Union - further detailed technical description of the subject matter of the contract is included in the Specification of Important Terms and Conditions of Purchase. 1. a wound infiltration kit consisting of: - a 19G x600 mm wound infiltration catheter with holes for the first 100 mm, reinforced with a steel spiral to ensure the drug flows even when the tissues are pressed against the catheter. a micro-perforation in a spiral line around the catheter, tightly and evenly distributed to ensure that the anaesthetic agent is distributed over the entire length of the perforation, within a radius of 3600 around the catheter.Catheter visible in X-ray and ultrasound - an entertaining catheter placement system integrated into the 18Gx116mm insertion cannula - an integrated filter and catheter attachment to the patient's body, tabs on the bottom of the mount to provide catheter stabilization - a flat round 0.2μm filter. pcs. 1002 Wound Infiltration Kit consisting of: - a 19G x600 mm wound infiltration catheter with holes for the first 150 mm, reinforced with a steel spiral to ensure drug flow even when tissues are pressed against the catheter. Micro-perforation in a spiral line around the catheter, tightly and evenly spaced to ensure that the anaesthetic agent is distributed over the entire length of the perforation, within a radius of 3600 around the catheter.Catheter visible in X-ray and ultrasound - an entertaining catheter placement system integrated into the 18Gx116mm insertion cannula - an integrated filter and catheter attachment to the patient's body, tabs on the bottom of the mount to provide catheter stabilization - a flat round 0.2μm filter. pcs. 1003 Wound infiltration kit consisting of: - a 19G x700 mm wound infiltration catheter with holes for the first 220 mm, reinforced with a steel spiral to ensure the drug flows even when the tissues are pressed against the catheter. Micro-perforation in a spiral line around the catheter, tightly and evenly spaced to ensure that the anaesthetic agent is distributed over the entire length of the perforation, within a radius of 3600 around the catheter.Catheter visible in X-ray and ultrasound - an entertaining catheter placement system integrated into the 18Gx116mm insertion cannula - an integrated filter and catheter attachment to the patient's body, tabs on the bottom of the mount to provide catheter stabilization - a flat round 0.2μm filter. pcs. 1004 Portable infusion system, completely latex and DEHP free, using an elastomeric tank with a nominal volume of 275 ml. Flow rate 5 ml/h. With 5 μm filter on the infusion line. Port to fill the device on the wood, equipped with a luer lock connection. Integrated mounting system of the device allows the patient to move freely during therapy. Infusion system tested for stability with ropivacaine and bupivacaine (include stability test in the offer). Single packed, apirogenic device. An infusion line terminated with a removable filter that automatically removes air while the device is being filled to prevent drug leakage. pcs. 500 1 PREPARATION SCISSORS SUPER SHARP TYPE JAMESON BENT DELICATE LENGTH 130 MM ENDS BLUNT BLUNTLY BLUNT 52 PREPARATION TICKS TYPE RUMEL BENT FIGURE TYPE 1 LENGTH 240 MM 53 SURGICAL VICE TYPE HEGAR-MAYO-SEELEY WITH RATCHET LENGTH 200 MM WORKING PART WITH HARD JAW INSERT CROSS-SEGMENTED STROKE 0,4 MM 54 ATRAUMATIC MICRO CLAMP TYPE BULLDOG 60MM JAW LENGTH 20 MM STRAIGHT 35 ATRAUMATIC MICRO CLAMP TYPE BULLDOG 57MM JAW LENGTH 17 MM BENT 36 VASCULAR TICKS WITH ATRAUMATIC TOOTH TYPE DERRA CURVED LENGTH CURVATURE 20 MM TOTAL LENGTH 170 MM. 47 VASCULAR TICKS WITH ATRAUMATIC DENTITION FOR OCCLUSION OF SECRETING VESSELS DE BAKEY-SATINSKY TYPE, LENGTH 240 MM, LENGTH 240 MM, LENGTH 1.5 MM, LENGTH 2.5 MM, LENGTH 2.5 MM. JAWS 76MM, ARCH WIDTH 40MM 28 PREPARATION TICKS TYPE MIXTER ATRAUMATIC (CARDIAC SURGERY) BENT LENGTH 250MM 29 ANATOMICAL TWEEZERS TYPE COOLEY DELICATE STRAIGHT WORKING PART TRANSVERSELY SERRATED LENGTH 200MM 810 ANATOMICAL TWEEZERS WITH ATRAUMATIC TEETH TYPE DE BAKEY BENT 40 DEGREES MOUTH WIDTH 2MM LENGTH 200 MM 411 RETRACTOR TYPE DULL WEITLANER 3X4 TEETH TOTAL LENGTH 130 MM 112 BONY LEVER BUCKET WIDTH 25 MM LENGHT 260 MM 213 BONE LEVER WIDTH 22 MM LENGTH 300 MM (ONE) 214 CARTILAGE TONGS TYPE BRICHER-GANSKE CURVED LENGTH 200 MM 615 VASCULAR TONGS HOPFNER TYPE LENGTH 165 MM LONGITUDINAL TEETH STROKE 0,7 MM 1 1 1 MAINTENANCE-FREE ALUMINIUM CONTAINER WITH A FIXED FILTER FOR 5000 STERILIZATION CYCLES. CONTAINER BATHTUB WITH DIMENSIONS 592X274X90MM, RED CONTAINER COVER WITH DIMENSIONS 593 X 294 X 37, INTERNAL STEEL BASKET WITH DIMENSIONS 540X253X76MM. IDENTIFICATION LABELS WITH UP TO 12 CHARACTERS, 2 PCS. EACH IN RED AND BLUE 22 MAINTENANCE-FREE ALUMINIUM CONTAINER WITH PERMANENT FILTER FOR UP TO 5000 STERILIZATION CYCLES. CONTAINER BATHTUB WITH DIMENSIONS 592X274X90MM, BLUE CONTAINER COVER WITH DIMENSIONS 593 X 294 X 37, INTERNAL STEEL BASKET WITH DIMENSIONS 540X253X76MM. IDENTIFICATION LABELS WITH UP TO 12 CHARACTERS, 2 PCS. EACH IN RED AND BLUE 23 MAINTENANCE-FREE ALUMINIUM CONTAINER WITH PERMANENT FILTER FOR UP TO 5000 STERILIZATION CYCLES. CONTAINER BATHTUB WITH DIMENSIONS 592X274X120MM, CONTAINER COVER IN GREEN WITH DIMENSIONS 593 X 294 X 37, INTERNAL STEEL BASKET WITH DIMENSIONS 540X253X106MM. IDENTIFICATION LABELS WITH THE POSSIBILITY OF DESCRIBING UP TO 12 CHARACTERS, 2 PCS. EACH IN RED AND BLUE 24 MAINTENANCE-FREE ALUMINIUM CONTAINER WITH A FIXED FILTER FOR UP TO 5000 STERILIZATION CYCLES. CONTAINER BATHTUB WITH DIMENSIONS 592X274X120MM, CONTAINER COVER IN GOLDEN COLOR WITH DIMENSIONS 593 X 294 X 37, INTERNAL STEEL BASKET WITH DIMENSIONS 540X253X106MM. IDENTIFICATIONAL ETICS WITH THE POSSIBILITY OF DESCRIPTION OF up to 12 SIGNAL SIGNIFICATIONS OF 2 SIGNES IN RED AND BLUE colours 2 1. Biopsy pliers length 1150 pcs. 3002 Biopsy Pliers Length 1550 pcs. 203 Disposable double-sided brush for cleaning inlets of endoscopic canals and channels pcs. 18004. One-sided brush for cleaning endoscopic canals pcs. 1205. Needle for transcutaneous aspiration biopsy 22G pcs. 606. Needle for a 21G transcutaneous aspiration biopsy, 22G pcs. 507. Needle for transcutaneous aspiration biopsy 19G pcs. 38th Needle for transcutaneous aspiration biopsy 25G pcs. 10 Parameters:Ad. 1- disposable biopsy pliers, teaspoons with needle-free window; - alligator jaw edges and smooth edges - optional; - tiltable teaspoons for tangential biopsy; - stainless steel teaspoons with two-step cutting; - Teflon casing safe for endoscopic biopsy canals; - tool length 1150 mm;- maximum diameter of the part introduced into endoscopes 1.9 mm; - minimum diameter of the working channel 2.0 mm; - teaspoon opening 5.0 mm, teaspoon capacity 4.0 mm; - sharp edges of pliers that grip diagnostic material well; - sterile 1 piece each; - gamma irradiated sterile.- documented compatibility with Olympus bronchofiberoscopes (we currently have endoscopes covered by warranty)Ad. 2 disposable biopsy pliers, oval spoons with window and oval spoons with window and needle (optional) - tilt spoons for tangent biopsy; - stainless steel spoons with two-stage cut and smooth edges; - Teflon casing safe for endoscopic biopsy canals; - tool length 1550 mm;- maximum diameter of the part introduced into endoscopes: 2.45 mm; - teaspoon opening: 6.5 mm; - teaspoon opening: 6.1 mm3; minimum diameter of the working channel: 2.8 mm; - sterile 1 piece each; - sharp edges of pliers that grip the diagnostic material well; - gamma irradiated.- documented compatibility with Olympus bronchofiberoscopes (we currently have endoscopes covered by warranty)Ad. 3- disposable double-sided brush for cleaning endoscopic canals and inlets; - working length 950 mm; - plastic tip to prevent scratching of endoscopic canals; - for endoscopic canals with a diameter of 2.0 mm - 3.2 mm; Ad. 4- disposable single-sided brush for cleaning narrow endoscopic canals; - working length 950 mm - bristle diameter 2.4 mm - bristle length 5 mm - endoscope canal diameter 1.0 mm - 1.5 mm; - compatible with Olympus EBUS (new, covered by warranty)Ad 5- disposable needle for aspiration biopsy under ultrasound control (EBUS - TBNA) - tool length 700mm, maximum needle blade extension (with removed stopwatch) 40mm,- minimum needle blade extension length 20mm;- diameter of needle blade 22G; - maximum diameter of part introduced into working channel 1,8mm; - minimum diameter of endoscope working channel 2,0mm; - at the end of needle blade there are holes at the end of the blade that strengthen the echo;- inside the tool there is a removable tangerine with a rounded tip and a handle ensuring constant needle patency; - it has a regulation of the extension of the casing (knob) and a slider-slider regulating the degree of extension of the needle; - on the control part there is a scale allowing to determine the degree of extension of the needle blade;- has a removable stopwatch limiting the needle penetration level not deeper than 20mm; - has a graphic marker informing about the complete hiding of the needle in the casing; Due to restrictions in standard forms used for publication of announcements in the Official Journal of the European Union - a further detailed technical description of the subject of the contract can be found in the Specification of Essential Terms of Contract. Set for evacuation and drainage of subdural hematomaSht. 50 Technical description:- screw-in evacuation socket - 1 pc,- disposable hand drill with drill and depth limiter - 1 pc,- 100ml suction pear with directional valve and drainpipe - 1 pc,- stainless steel opener - 1 pc,- stainless steel anatomical tweezers - 1 pc,- stainless steel surgical tweezers - 1 pc,- 15 scalpel with holder - 1 pc,- scalpel 11 with handle - 1pc,- stainless steel needle vice - 1pc,- spinal needle 18Gx3,5" - serviette with a window to cover the patient's head - set wrapped in a tablecloth May - sterile set Programmable valve chamber peritoneal with a set of drains1 set = valve + ventricular drain + intraperitoneal drain - programmable valve type in-line, without anti-synthetic 40pcs,- ventricular drain 40pcs.Programmable peritoneal-chamber programmable valve with a set of drains.Technical description:- programmable "in-line" valve without anti-sound mechanism - possibility of non-invasive setting of flow pressure - 5 degrees of valve mechanism settings within the flow range from 15 to 220 ml/h- valve dimensions 16x32x8mm - valve with a reservoir of cerebrospinal fluid with the possibility of puncture and fluid aspiration, - ventricular drain length 23cm with distance markers - external diameter of the drain 2.5mm, internal diameter 1.3mm - distal section of the drain length 1.3mm - drainage tube with the possibility of puncture and aspiration of the fluid, - ventricular drain length 23cm with distance markers - external diameter of the drain 2.5mm, internal diameter 1.3mm - distal section of the drain length 1.3mm. 1.6cm containing 4 rows of 8 drainage holes in each row - drain compatible with programmable valves - retroperitoneal drain 120cm long, with distance markers, - external diameter of the drain 2.5mm, internal 1.3mm, open end containing 8 slotted holes, - drain compatible with programmable valves - free of charge use of the programmer for the duration of the contract, after the termination of the contract - retroperitoneal drain 40pcs. Paper and foil backing roll 350Parameters:j.m. specification of requirementsPhysical Properties cm width of tissue paper 51- colour of tissue paper green- number of layers of tissue paper 2G/m2 weight of tissue paper 16.5Cm width of film 50±1- appearance of edges without jaggedΜm thickness of film 20±2Cm perforation 50±2- surface crushed (pressed) - discolouration not allowedG/m2 minimum absorbency 160Length 30Length 30Length - mechanical damage e.g. mechanical damage e.g: holes in tissue paper or foil, tears are not allowed - smell is not allowed - smell is not allowedOur advantages - not permeable - External nebulizer designed for SERVO (Maquet) ventilators pcs. 2 Parameters: Portable nebulizer compatible with Maquet ventilator, declared to newborn, with the possibility of connecting to the breathing circuit of the newborn. Selectable nebulization cycle 15 and 30 min, with automatic shutdown after the specified time. It does not contain natural latex. Device with electromagnetic compatibility (EMC). Possibility of attaching the control module to a standard IV pole. Power supply also from a battery. Flushing pump OFP-2 pcs. 1 Parameter required/expected Parameter offered1. Flushing pump cooperating with Water Jet channel of Olympus endoscopes and endoscopic tools having a channel for water injection required2. Medical device controlled by a microprocessor required3. LED indicator to indicate the current pump power required4. Pump control via foot controller and buttons on existing Olympus endoscopes required5. Flow rate control required6. Water container with a capacity of at least 2000 ml, autoclavable required7. A set of drains - minimum 50 pcs. expected8. Pump control connection hose from your existing EVIS Exera III CV 190 processor required 2,000 ml bag for daily urine collection. 100 000Parameters:- bag capacity - 2000 ml,- medical PVC, latex-free,- tear-proof,- accurate measuring scale, min. every 100 ml,- non-return valve,- tight drain valve - "T" type crosswise, - connecting drain ended with universal step connector, plugged length of drain min. 90cm,- drainage made of a material preventing it from bending and twisting, ensuring free and effective urine outflow,- reinforced holes for the hanger,- sterile,- individually packaged, foil packaging,- expiry date and serial number on a single package. Precutaneous micro catheter introduced peripherally by means of a torn G-20 needle, intended for chronic use, made of polyurethane, shading the X-ray markers every 1 cm. Size 2F (0.3x0.6mm) and length 15 cm. A catheter terminated with flexible wings. Built-in protection against bending of the catheter's light pcs. 252 Precutaneous micro catheter introduced peripherally by means of a torn G-20 needle, designed for chronic use, made of polyurethane, shading the X-ray markers every 1 cm. Size 2F (0.3x0.6mm) and length 30 cm. A catheter terminated with flexible wings. Built-in protection against bending of the catheter's light pcs. Umbilical cord catheter made of medical PVC, shadingW x-ray, length markers, Roz. 3,5-5F length 40 cm, pcs. Cord catheter made of polyurethane, shaded in X-rays, used for veins or arteries, marked from 4 to 23 cm. In the set with the faucetZ with the possibility of marking the vein, the size of the artery is from 3.5-5F length 40cm. 255 Premicath- 1F/28G Percutaneous catheter inserted peripherally with a short 24G Bioflow cannula (diameter 0.7 mm, length 19 mm), intended for chronic use, made of polyurethane, shaded in X-ray marked every 1cm, 20 cm long with a guide, equipped with an 8 cm extension of the PremicathSzt type. 306 Premicath- 1F/28G Percutaneous catheter inserted peripherally with a split needle 24 G with an external diameter of 0.7 mm length 18 mm, with a metal guide made of polyurethane shading X-ray marked every 1 cm with a length of 20 cm, equipped with an extension of 8 cm type Premicath pcs. 207 Neonatological infusion filter 0.2 um maintained for 96 hours, ended with an extension of 5 cm pcs. 2008 Neonatological lipid filter 1.2 um maintained for 24 hours ended with an extension of 5 cm pcs. A contrasting X-ray polyurethane catheter for simultaneous administration or transfusion of solutions and/or medicines, distance markers every cm from 4 cm to the distal end, the user can choose between two variants of the inserter: needle or I.V. cannula. 20

Opportunity closing date
12 July 2019
Value of contract
to be confirmed

About the buyer

Address
Specjalistyczny Szpital im. dra Alfreda Sokołowskiego ul. Sokołowskiego 4 Wałbrzych 58-309 Poland
Contact
dorota.piekarz@zdrowie.walbrzych.pl

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?