Poland - Medical kits
For more information and to make a bid you will need to go to the third party website.
Details
Provided by
- Opportunity closing date
- 19 August 2019
- Opportunity publication date
- 16 July 2019
- Category
- 33141620: Medical kits
- Value of contract
- to be confirmed
- Your guide to exporting
Description
Filters for removing leukocytes from platelet cell concentrates. Size of the order: Equipped with a venting system to guarantee closed system filtration.4. A natural polymer filter to prevent platelet activation during filtration.5. For laboratory filtration of 1 apheresis unit or 1 KKP.6 sink unit.Filtration time ≤ 15 minutes.7 Filtration efficiency to a level considered to prevent alloimmunization (leukocyte count <1x106/unit).8 The volume of preparation remaining in the system shall not exceed 15 %.9. Filters for removing leukocytes from red blood cell concentrates. Size of the order: 5 212 pcs.1. Polyvinyl chloride receiving container for UKKCz 2. 500-600 ml transfer container integrated in the filter 3. Filters made of transparent plastic for visual inspection of the filtering process 4. At least 3rd generation anti-leucocyte filter for KKCz filtration 5.Filter purification system after filtration with sterile air and by-pass drain (to vent the transfer container and achieve maximum efficiency).6. Filter purification with sterile air does not shorten the expiry date of the filtered KKCz (i.e. 42 days from the date of collection).7.A transfer container equipped with an additional drain for quality control purposes.9. The filter has a flexible and thin-walled drain.10. The filtration time does not exceed 20 min.11. The volume of blood remaining in the system does not exceed 15 % of the original volume.12.Filtration efficiency ≥ 5 log (number of leukocytes less than 1x106/one-day), in at least 90 % of tested units, with the temperature of the filtered component within the range + 2oC to 24oC.13. Equipped with a prefilter - 160-200 μm or optionally without a prefilter, if the proper filter also serves as a prefilter.14 It should not release physical and chemical substances into the blood and should not cause hemolysis.15Unambiguous marking of the transfer container by entering the product code and series.16 On the home label of each filtration set, the LOT and REF numbers of the container in numerical form and in the form of a bar code compliant with the ISBT standard (EAN 128), CE number, manufacturer's name, expiry date.17. Sets of only one series.18. Only one series of filters in a single carton.19. Each carton must have an information leaflet in Polish explaining the filter operation and storage conditions. Triple top-to-bottom containers for blood collection. Size of the order: 30 685 pieces Description of the subject of the contract1. Containers for blood collection, production of red blood cell concentrate without leukocytarno-platelets in enrichment solution of freshly frozen plasma (possible production of platelets from a platelet).2. Empty upper container with max. capacity. 600 ml, min. 500 ml, middle container with 63 ml CPD for collecting 450 ml of blood and bottom container containing 105 ml+/- 5 ml of SAGM or ADSOL fluid with max volume 600 ml, min. All containers are made of plastic that can store both the CRC, plasma and platelets.4 They allow 450 ml of whole blood to be collected.5 No strontium or preservative fluid changes.6. The construction of the needle guarantees prevention of cutting out of skin, subcutaneous tissue and veins.7 All drains are flexible, easy to roll, allow for permanent welds and the operation of weight mixer clamps.8. Printing on drains required only on the drains used for making pilots.9The donor drain can be connected in the lower or upper part of the CPD.10 container. The length of the drain between the mother container and the plasma container is 58 cm +/- 5 cm.11. The length of the drain between the mother container and the CZK container is 45 cm +/- 5 cm.12. The length of the drain from the container to the base of the needle max. 165 cm min. 120 cm.13. Length of the drain running to the sample container max. 30 cm +/- 5 cm, min. 20 cm +/- 5 cm.14. Labels made in accordance with ISO and ISBT requirements. Labels made of plastic, resistant to mechanical damage, allow you to stick your own label.15. Permissible marking on labels in the form of pictograms. Labels contain information about the type and amount of preservative fluid and the intended use of the container, container number and serial number in the form of a barcode.16. Containers packed in individual packages, individually or double made of transparent foil, ensuring tightness and sterility. The type of sterilisation shall permit the use of a container within 10 days of the opening of the direct or indirect packaging.17. Containers containing a container for first blood sampling with a port for vacuum sampling. The drain and the drain running to the sample container are equipped with clamps preventing their removal from the drains.18. The connections facilitating the flow between the containers are transparent and can be easily broken off.19. ADSOL or SAGM enrichment solution makes it possible to store the obtained KKCz in a standard temperature range from 2 to 6 degrees C for 42 days.20. The containers are admitted to trading on the territory of Poland.21. The contractor will attach a quality control certificate to each delivery for each series. Panel 3 Blood panel for allo-antibody review studies, a set of 3 different donors of phenotypes:DCCweeDccEEDccee Blood group O cells in which the expression of the following antigens should be expressed as a minimum: C, Cw, c, D, E, E, e, K, k, Fya, Fyb, Jka, Jkb S, s, M, N, P1, Lea, Leb. Homozygotic expression of Fya, Fyb, Jka, Jkb, M, N, S, S, s antigens required. Standard cells for antiglobulin antibody review tests. One set contains 3 bottles with drops of not more than 5 ml. Red cells must be preserved, ready to use.100% sensitivity and diagnostic specificity.order quantity: 288 ml.
- Opportunity closing date
- 19 August 2019
- Value of contract
- to be confirmed
About the buyer
- Address
- Wojskowe Centrum Krwiodawstwa i Krwiolecznictwa Samodzielny Publiczny Zakład Opieki Zdrowotnej ul. Koszykowa 78 Warszawa 00-671 Poland
- Contact
- zp@wckik.pl
The deadline to apply for this opportunity has passed.
Visit the
opportunities page
to find another.