Poland - Medical devices

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
11 August 2020
Opportunity publication date
28 July 2020
Category
33100000: Me
Value of contract
to be confirmed
Your guide to exporting
Report opportunity

Description

Open tender for the supply of orthopaedic disposable equipment
Titanium Titanium Button with holes for the attachment of a tibial ACL graft Titanium Implants for arthroscopic reconstruction of one threaded, extra strengthTitanium Implants for arthroscopic reconstruction of rotators and biceps tenode with two and three threads extra strength. Biochapable, arrowheads for suturing the meniscus. .Sterile arrows mounted on a feeder, with teeth preventing its reversal . Steel plates for an opening tibial osteotomy Steel plates for an opening femoral osteotomy. Nitinol needles for sewing meniscus Marker sterile, non-toxic, quick-drying, disinfectant-resistant, purple ink, measuring scale on the body of the pen - 5cm. Bipolar, tungsten electrode for removing and modifying soft tissues in the knee, shoulder and small joints, profiled properly under three different angles with suction, working length min. 12 cm and 30˚ without suction, compatible with the coagulation lent by the Contractor, with the possibility of cutting tissues with the electrode edge. Manual control system required. Sterile kit for sewing meniscus, allowing to put on min. Sterile meniscus sewing set allowing to put on min. 4 stitches at a time. Single-cassette drain complete with shaver drain, compatible with the 24KDay pump 24KDay pump 24KPatient drain connected to the 24KDay cassette 24K Reusable bone and soft tissue shaver tips in sizes 3.5mm; 4.5mm;5.5mm. Bone and soft tissue shaver tips compatible with Linvatec's system or hire a console and 5 shavers with compatible tips. Disposable blades compatible with Aesculap Sp. z o.o. drives. - Different sizes Femoral and acetabular inspection netsThe anatomically right and left inspection bins with screws Sterile needles for the reconstruction of the rotator cone to the Viper owned by the orderer or the loan of a tool compatible with needles from the contract Carbon implants for cartilage reconstruction. Screws (osteointegration screws) for ligament reconstruction with bone tissue reconstruction in sizes min. 7-11 mm, average length min. 25 - 30 mm. Plates for femoral anastomosis perimplantation fractures - cable system (ropes) Spike implants for reconstruction of the rim single-charged with an increased resilience threadSpike implants charged with 2 threads for reconstruction of the rotator cone Bone replacement material in the form of granules 1-4 mm packaged in 10 mlBone replacement material in 1-4 mm granules packaged in 20 ml Tibial anchorage implants for ACL reconstruction consisting of a screw and washerSmooth cannulas for shoulder arthroscopyElastic shoulder cannulas. Locking by means of transverse striations, non-threaded, drain blocking membrane, complete with metal, cannulated trocar, in various sizes.Strong and non-absorbable thread. Minimum breakaway strength of the thread 7N Knotless PEEK version for stabilizing the rotator cone, screw-on implant available from 3mm-6mm. Folded into a disposable screwdriver with a marker that allows full control and evaluation of the correct implant placement. The implant allows intraoperative control of the transplant voltage. 1.5mm-3mm thick tape, min. 15 cm available in two colours for better visualization, finished with a thread of 2 mm diameter. Implants for the filling of cartilaginous and bone defects, prepared in-situ bio-polymer, bio-compatible poly-glucosamine implant for the filling of cartilaginous and bone defects and permanent replacement of damaged joint cartilage. Hardening in the polymerization process at body temperature . Adapted for administration via syringe in arthroscopic procedure . Implant for the arthroscopic reconstruction of the ring made of strong tape, placed on a disposable feeder. The implant is interlaced with one super-powerful thread size # 2 . Single packed in sterile packaging. Implant for arthroscopic reconstruction of the ring made of strong tape, placed on a flexible, disposable tray. The implant is intertwined with two super strong #2 size threads. Single packed in sterile packaging. Implant for arthroscopic reconstruction of rotator cone made of strong tape, placed on a disposable feeder. The implant is intertwined with two #2 size super strong threads. Single packed in sterile packaging.Flexible drill for the implant. ENDOPROTEZA SINGLE BALANCE STAGE Synthetic cortical paste for bone restorationCortical paste for bone restorationCortical paste for preparation directly in a syringe. 2,5 cm3, 5 cm3, 10 cm3 - the basic component - calcium phosphate - is introduced into the interbone space through variously shaped needles - material which does not emit heat during insertion and integration - compression strength of about 55Mpa - full strength obtained after 24 hours from insertion - biocompatible and bio-soluble - neutral reaction Ph - sterile packaging. Complete remodeling time from 6 to 18 months. 3.0 cm3, 5 cm3.10 cm3 - basic component - calcium phosphate - introduced into the intercostal space through variously shaped needles - material which does not emit heat when introduced and merged - compressive strength approx. 55Mpa - full strength obtained 24 hours after introduction - biocompatible and bio-soluble - neutral reaction Ph - sterile packaging. Full conversion time from 6 to 18 months.Capacity 2.5 or 3.0 cm3Capacity 5.0 cm3Capacity 10.0 cm3Paste injection cannulas: Straight/bentDiameter 3.3 mm, 2.6 mm, 2.0 mm, 1.6 mmLength 5, 7.5, 10, 12.5 mmSynthetic bone restoration granulesSynthetic bone restoration granules ready to be used in a container with a capacity of 5.0 cm3Capacity 5.0 cm3Capacity 10.0 cm3Injection cannula: Straight/bent, 2. 1 cm3, 2.5 cm3, 10 cm3 and 20 cm3 - chemical composition - calcium beta tri triphosphate - introduced into the interbone space - material which does not emit heat when introduced - compressive strength approx. 7.5Mpa. Biocompatible material - absorbed and rebuilt into living bone. Granulate grain diameter in three groups of choice 0.7 - 1.4 mm; 1.4 - 2.8 mm; 2.8 - 5.6 mm. Sterile packaging. Complete reconstruction time from 6 to 18 months.1 cm3Pack 1 cm3Pack 2.5 cm3Pack 5 cm3Pack 10 cm3Anterior ligament reconstruction system based on coronary fixation with a longitudinal insert. The plate with 2 holes is made of a rectangular titanium alloy with rounded sides permanently connected to a loop of non-absorbent thread in lengths from 15 to 60 mm with a pitch of 5 mm. The implant comes complete with a thread to be pulled through the channels. Sterile ImplantTitanium tibial button with a bulge under the tibial canal to avoid tibial movements, with holes. Sterile implantRusha nail Ø 2,4 L 50 - 240 mmRusha nail Ø 3,2 L 100 - 260 mmRusha nail Ø 4,0 L 200 - 360 mmRusha nail Ø 4,8 L 200 - 360 mmRusha nail Ø 6 - 6,4 L 260 - 420 mmEnder nails 4,0 - 300 - 450; 4,5 - 300 - 450Grot Steinmann A 4,0 x 150 - 250Grot Steinmann A 4,5 x 200 - 220Grot Steinmann A 5,0 x 210 - 250Drut Kirschner triangle 0,8 x 70 - 150 mm - 210; 310Drut Kirschner triangle 1,0 x 150 mm; 210; 310Drut Kirschner triangle 1,2 x 150 mm; 210; 310Drut Kirschner Trimble 1,4 x 150 mm; 210; 310Drut Kirschner Trimble 1,6 x 150 mm; 210; 310Drut Kirschner Trimble 1,8 x 150 mm; 210; 310Drut Kirschner Trimble 2,0 x 150 mm; 210; 310Drut Kirschner Trimble 2,2 x 150 mm; 210; 310; 310Drut Kirschner Trimble 2.4 x 150 mm; 210; 310Drut Kirschner Bone for Cerkler 0.5 - 2.0 Disposable blades compatible with Linvatec drives - different sizes Disposable blades compatible with Stryker drives. z o.o. - different sizes

Opportunity closing date
11 August 2020
Value of contract
to be confirmed

About the buyer

Address
Samodzielny Publiczny Zakład Opieki Zdrowotnej Ministerstwa Spraw Wewnętrznych i Administracji w Białymstoku im. Mariana Zyndrama-Kościałkowskiego ul. Fabryczna 27 Białystok 15-471 Poland
Contact
zamowienia@zozmswia.bialystok.pl

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?