Poland - Angioplasty devices

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
02 August 2023
Opportunity publication date
27 June 2023
Category
33111730
Value of contract
to be confirmed
Your guide to exporting
Report opportunity

Description

The subject matter of the contract includes sale and delivery of assortment necessary for Vascular Surgery of Edmund Biernacki Specialist Hospital in Mielec, assortment included in 35 Assortment Groups
1 Self-expandable peripheral vascular stent-system profile 6F-compatible with 0.035"-stent made of nitinol-with spiral, micro mesh design-system allows one-handed release of the stent using a knob or slide located on the handle-6 shading markers on each end of the stent-stent diameters: 4 - 9 mm-stent lengths: 20 - 150 mm-lengths of delivery system-80 and 125 cm pcs. 35 1 Catheter: Sterile two-channel embolectomy catheter-has lumen for guidewire-possible to administer contrast and flush-balloon diameter 6, 8, 10, 12, 14, 16 mm-catheter diameter 3, 4, 5, 6, 7, 8F-compatible with guidewire 0.016"; 0.018"; 0.025"; 0.027"; 0.035"; 0.038"-lengths 40, 80 cm pcs. 602 Sterile Fogarty embolectomy catheter, single-channel, made of PVC with mandrene, soft spherical tip, terminated with luer-lock cap a Size F 3 length 80cm pcs 40b Size F 4 length 80cm pcs 100c Size. F 5 length 80cm pcs 50d Rozm. F 6 length 80cm pcs 20e Rozm. F 7 length 80cm pcs 5d Rozm. F 8 length 80cm pcs 53 Silicone abdominal drainage length 40cm , without side holes a Rozm. 10F pcs 40b Rozm. 12F pcs. 40 1 Hybrid nitinol stent for carotid artery -Rapid Exchange type delivery system -stent with open stent targets and closed targets in the middle part of the stent -required stent length range 20-50 mm -required stent diameter range 4-10 mm -conical stents available -insertion system size 5F -platinum markers at the end of the stent pcs. 15 1 Self-expanding carotid stent: -stent adapted to carotid vessels -made of steel-cobalt alloy -delivery system accepting 0.014" guidewire, monorail -delivery catheter length 135 cm -delivery system diameter 5 and 5.9F -stent woven in tabular mesh shape, with closed cell geometry -stent with high flexibility, softness and adaptability to the shape of the vessel and its changing diameter - common carotid artery - internal carotid artery -stent with reassembly - completely repositionable -diameters: 4-10 mm -lengths: 30/40/50 mm -good visibility of the stent under fluoroscopy, without markers pcs 102 Guidewire with filter for neuroprotection: - 0.014" guidewire 190 cm and 300 cm long with platinum soft moldable tip - guidewire positioned off-center to the filter basket - filter basket fixed in a movable way - guaranteeing rotation on the guidewire - filter in the form of a self-expandable nitinol loop with a basket/membrane with a porosity of 110 microns - one size to fit different vessel diameters in the range of 3,5 to 5.5 mm -delivery cage in Monorail system with 3.2F passage profile pcs. 303 Balloon catheters for carotid artery. Catheters in RX (Monorail) system with lengths of 80, 90, 135, 150 cm, compatible with 0.018 " guidewire, diameters from 2mm to 7mm (in 0.5mm increments) and 8mm. Lengths: 10/15/20/30/40/60/80/100/120/150/220 mm, compatible with 4F and 5F sheath for 7mm and 8mm diameters, RBP 14 atm and 12ATM for 8mm diameter pcs 304 Cutting balloon catheter:- catheter compatible with 0.014" (rapid exchange) and 0.018" guidewire. (OTW)-balloon diameters from 2 mm to 8 mm-balloon lengths: 1.5 cm and 2 cm-number of atherotomes: 3 or 4-catheter length: 50 cm to 140 cm-compatible with 6 or 7 F sheath depending on diameter-RBP 10 and 12 atm-nominal pressure 8 ATM-medium burst pressure 12 ATM pcs 105 ICE-coated hydrophilic guidewire in the distal part. Diameter 0.018", lengths 110/150/200/300cm. Shapable end with a length of 2cm. Distal soft part in lengths of 8 and 12cm. Tip stiffnesses of 6g and 8g. 304V stainless steel core pcs 106 Guiding catheter reinforced with double tungsten weave and stainless steel. Catheter with diameters 6/7/8F and large inner lumen: 6F - 0.070", 7F - 0.081", 8F - 0.091 "Lengths: 55 and 90cm. Inner coating made of PTFE and outer coating made of Arnitel. Soft, atraumatic tip in 17 shape variants pcs 10 1 System for targeted thrombolysis: - includes a catheter with a hemostatic valve at the distal end of the catheter, Y-connector - available diameters: 4F and 5F - available system lengths: 45 cm, 90 cm, 135 cm - infusion segment length:- 45 cm systems: 10 cm and 20 cm - 90 cm and 135 cm systems: 5 cm, 10 cm, 20 cm, 30 cm, 40 cm, 50 cm- Compatible with 0.035 "guidewire- Holes made spirally around the axis of the catheter to ensure uniform delivery of the therapeutic agent to the entire lumen of the lesion- Holes divided into sequences of increasing diameter to ensure uniform infusion pressure along the entire length of the infusion segment of the catheter- Number of holes: 8 over a length of 1 cm- Laser technology for making the holes to reduce the risk of clogging during infusion Pistol syringe- Pistol delivery system allowing both pulsatile and uniform delivery of the therapeutic agent with adjustable volume from 0.0 to 1.0ml pcs. 302 Syringe-Capacity 1ml, 3ml, 6ml, 10ml, 20ml-Transparent body made of polycarbonate-Rubber plunger tip-Notch screw-on male tips-Different plunger colors available pcs. 603 Torqer: -compatible with guide from 0.014" -0.018" pcs. 304 Torqer: -with the possibility to use also in hydrophilic guides -one-handed operation by means of a push-button mechanism -no metal elements that can damage the hydrophilic coating -carbon handle for easy control and rotation -compatible with guide from 0.018" - 0.035" pcs 305 Y connector pcs 406 Ramps 2, 3, 4 -way: -pressure resistance of 200 PSI or 500 PSI (color-coded) -transparent polycarbonate body -high throughput (ramp inner lumen 0.093") -precise faucets -On and OFF versions available -available ramps with full and narrow body -rotatable luer left or right pcs. 27 Radiology diagnostic catheters:-Wide range of curvatures: Bentson (1; 2); Berenstein; Cobra (1; 2); Headhunter (1; 3); Hockey Stick; Hook (0.8; 1.0); KA2; Mani; Mikaelsson; Modified Cerebral; Modified Hook (1; 2; 3); Modified Simmons; Motarjeme; Motarjeme Cane; Multipurpose A1; MW2; Newton (1; 2; 3; 4); Osborne; Renal Double Curve; Reuter; RBI; RIM; Shepherd Hook (0.8; 1.0); Simmons (1; 2); Straight Selective; Vertebral; Shepherd Flush; Ultra Bolus Flush; Modified Bolus Flush; Pigtail Flush; Straight Flush; Modified Hook Flush; UAC-Available sizes: 4F and 5F-Shaft material provides excellent flexibility and eliminates the risk of kinking while keeping the tip atraumatic-The corrugated transition between the hub and the saft makes it easy to handle the catheter with wet gloves-Perfectly visible in scopy-have a shadow tip-Catheters reinforced with steel braid-Catheters with a distal hole and with a distal hole and side holes-Perfect pushability, rotation transfer and maneuverability-Large internal lumen for high flow rate-Compatible with 0.035" guidewire - 0.038"-Catheter lengths in cm - 30,40,65,80,90,100,110,125 cm-Tapered tip for easy ostium entry-Perfect shape memory-Available fistula catheters in 30 cm lengths and curvatures: Pigtail; Cobra 1 Mod; RIM; KA2; Straight; Berenstein-Pressure 1200 PSI pcs. 508 Analog inflator, pressure range up to 30 atm, capacity 20 ml, transparent polycarbonate body allowing observation of the fluid column, angled pressure gauge with fluorescent dial and vacuum indicator, 33 cm long high-pressure tubing, three-way faucet included, 5 ml safety space to minimize the risk of air bubbles entering the balloon during inflation, trigger mechanism for rapid deflation, safety lock to prevent accidental deflation pcs. 150 1 Self-expandable peripheral stent graft:-Made of nitinol internally coated with PTFE;-Seamless connection of the stent framework with the covering material -laminated welds -Diameter 5-13 mm, -Compatible with guidewires: 0.014"; 0.018"; 0.035", -telescoping stent grafts can be connected, -internal surface with heparin coating, -insertion set diameter 6-12F, -flexible system allows implantation in tortuous peripheral vessels.1a-length of 5 cm;1b-length of 10 cm;1c-length of 15 cm;1d-length of 25 cm pcs 25 1 Abdominal aortic stent graft with infrarenal fixation system- bifurcated with multi-modular design- made of PTFE-coated nitinol wire- infrarenal fixation in the form of hooks- seamless connection of the stent graft skeleton with covering (laminated welds)- wide range of sizes: aortic part - to aortic diameter from 19 to 32 mm, iliac part - to iliac arteries diameter from 8 to 25 mm -possibility of repositioning the main arm of the stent graft allowing precise positioning of its upper part under the renal arteries -very good visibility on X-ray (shadowing markers) -low profile of the insertion set - from 12 Fr to 18 Fr -insertion sleeves, two rigid guidewires and balloon catheter included -two-piece set (main arm and contralateral leg) pcs 5 1 Catheters for endovascular surgery 4 / 5 F: -catheter tip stable and atraumatic, contoured to allow selective arterial cannulation -catheter constructed of polyurethane -marker at catheter tip - "glowing" in x-ray catheter tip -catheter reinforced with steel braid single for 5 F and double for 4 F-hydrophilic coating -good steerability 1:1 -4F or 4.1F outer diameter, with inner diameter = or >0.042" flow rate greater than 16.7 ml/s -5F outer diameter, with inner diameter = or >0.048" and flow rate greater than 21 ml/s -6F outer diameter, with inner diameter = or >0.048" and flow rate greater than 26 ml/s -Tip shape types: Renal, Benton, Headhunter, Newton, Mani, Mulitipurpose, Simmons, J-Curve, Cobra, Sheoard Hook, Celiac, Trunk, Left carotid, Verbatral, COE 2, Sidewinder, Straight, Straight Tapered, Non Tapered, Angled -Pressure capabilities: 750 PSI for 4F and 1000 PSI for 5F-possible to order tip type as needed pcs 6502 Diagnostic Pigtail catheters with 8 holes 4F and 5F 65, 70, 110 cm pcs. 1003 Calibrated Pigtail 5F catheter 110 cm, 6 to 8 side holes at the distal end, marked with gold markers in the distal section of the catheter for at least 20cm, the end of the diagnostic catheter perfectly visible in x-rays, localized every 1cm on the marked section pcs. 304 Shirt with dilator, needle and guidewire -angle bend resistant with hemostatic valve and attached side tap -atraumatic tip highly visible in x-rays -smooth transition between cannula and dilator -lengths 11, 23, 35 cm -in set present metal mini guidewire and needle -set or needle packaged separately, facilitating entry into selected vessel -packages of 1 pc. pcs 8504a Needle for item 4 pcs 8505 Reinforced guiding catheters with shaped tip to facilitate entry into the selected vessel -good controllability -types of shaped tip: Hokey Stik, Cobra, Contrlateral, Renal, Headhunter, Cerebral, Burke, Multipurpose, Straight -silicone hemostatic valve -soft and atraumatic tip -marker at end of catheter - "glowing" in x-ray catheter tip -coating of catheter with PTFE material -reinforced shaft -length of catheter 55 and 90 or 95 cm and 125 cm-large inner diameter, with minimal outer diameter-available sizes from 6 to 10 F pcs. 506 Diagnostic catheter: -diameter range 5-7 F -length min. 100 cm (for Pigtail catheter - min. 110 cm)-flat catheter reinforcement for good maneuverability and resistance to kinking -availability of two types of catheter materials: polyurethane and nylon -curvatures: Judkins Right (3.5 - 5), Judkins Left (3.5 - 6), Amplatz, Multipurpose -Pigtail with 6 side holes (straight and "angled" 145° and 155°, LCB, RCB, IM, Sones -Inner diameter min. 0.047" - for 5 F catheter and min. 0.057" - for 6F catheter - flow rate - min. 32 ml/s - for 6 F catheter -soft, atraumatic tip -good visibility in scopy pcs. 507 Amplatz J 260 cm 0.035 guidewire:-soft atraumatic tip "J" type bendable tip, length 3 cm -good contrasting in x-ray -stem of the guidewire monofilament with different degrees of tip tapering -steel braid on the guidewire shaft -very rigid monofilament guidewire with flexible tip -flexible tip in lengths of 3 cm and 7 cm -guidewire coating with PTFE or Teflon -can be converted to Super Stiff guidewire pcs. 90 1 Fixed-temperature p/stiff filter: -permanent-temporal p/embolic filter for vena cava -possibility to remove filter up to 12 days after implantation or permanent implantation -filter constructed of nitinol skeleton -self-expandable filter with thermal shape memory -natural filter diameter 35mm -.length of non-expanded filter 67mm -fitting up to 30mm vessel width -filter basket design symmetrical -SDS (insertion system) 6F -set length 55 or 90 cm -filter used universally (femoral, jugular), with dual filtration -filter guide covered with PTFE and Teflon 0.035" with 3mm J-shaped tip, 150 or 260cm long -6F introducer sheath with marker on tip, clearly visible in x-ray images pcs 22 Removal kit pcs 2 1 High-pressure flexible extenders, made of polyurethane, reinforced to withstand pressures up to 1200 psi, Luer-type tips, bend-resistant, lengths from 25 to 200 cm pcs 60 1 OTW balloon catheter for iliac artery and popliteal procedures -compatible with 0.035" or 0.018" guidewires -compatible with 4-7 F shunts -range of available diameters from 2 to 12 mm -range of available lengths from 20 to 300 mm -available usable lengths of the insertion system 80, 130, 180 cm -the manufacturing technology used prevents the balloon from curving after inflation pcs. 4002 Freepac-coated hydrophilic balloon catheter-composed of urea particles and Palitaxel, Palitaxel dose 3ug/mm2, drug release time from 30 to 60 sec -available balloon diameters 4.00; 4.50; 5.00; 6.00; 7.0mm -available balloon lengths: 20, 40, 60, 80, 120, 150 -available versions compatible with 0.018"; 0.035" guidewire pcs 403 OTW balloon catheter for below-the-knee procedures -compatible with 0.014" guidewire -available diameters from 1.4 to 4 mm -available lengths: 20 mm, 40 mm, 80 mm, 120 mm, 150 mm, 210 mm; for 210 mm length, versions with tapered /conical balloon available -available insertion set lengths of 120 cm and 150 cm, enlarged balloon inflation channel lumen pcs. 1004 OVER THE WIRE catheter:-a catheter to assist in the passage of heavily calcified lesions in anatomically difficult arteries below the knee -compatible with 0.014"; 0.018" guidewire. and 0.035"-all sizes compatible with 5F sheath-available lengths 135 cm, 150 cm pcs 205 Self-expandable peripheral vascular stent with introducer system:-nitinol, markers on both ends, diameter from 5-8mm-length from 20mm-150mm-compatible with 0.035'' guidewire and 5F introducer-delivery system lengths 80,120,150cm pcs. 106 Self-expandable peripheral vascular stent with insertion system:-nitinol, markers on both ends, diameter from 5-14mm-length from 20mm-200mm-compatible with 0.035'' guidewire and 6F introducer-delivery system length 80,120cm pcs. 207 Catheter with integrated rotating blade for intravascular atherosclerotic plaque excision:-compatible with 6-7F shunts-disposable, battery-operated drive kit-compatible with 0.014 "guidewire pcs. 108 System allowing use of independent 0.014" and 0.018" guidewire, OTW or RX system of choice, compatible with 6F guiding catheter. 3.2F passage profile. Filter constructed of heparinized nitinol thread woven into a basket, can be used in tortuous vessels. Filter skeleton made of gold wire. Five sizes 3-7mm, for vessels with a diameter of 2-7mm. Use in carotid, coronary, peripheral arteries pcs 10 1 Pressure syringes for angioplasty 20 and 30 atm:: -ergonomic syringe design for easy use -gun-shaped handle easy to use with left or right hand -maximum pressure of 20 atm and 30 atm. -syringe with a capacity of 20 ml, made of transparent material -syringe design for precise inflation as well as rapid deflation -protection against uncontrolled deflation -manometer dial covered with luminescent substance -possibility to generate pressures in a shaded room -readable manometer dial - dial graduation: for 20 atm. every 0.5 atm. for the 30 atm. model every 1 atm pcs 850 1 Neuroprotection system -flow-stop neuroprotection system -minimum sheath size 8F -guide 0.035" -profile of distal 5F -maximum balloon sizes-proximal 13 mm, distal 6 mm -working channel for 8F 0.069" -very good maneuverability -system resistant to kinking and kink pcs 2 1 Stentgraft for abdominal aorta, multi-piece, nitinol -set: -abdominal stent graft with suprarenal fixation - with anchoring elements in the aortic wall, located above the stent graft covering -first, free stent graft segment of not more than 15 mm in length, containing min.10 elements (needles, hooks, etc.) anchoring the stent graft in the aorta -made of polyester-coated nitinol crowns and allowing safe MRI imaging with a field induction of 3 Tesla (temperature rise of less than 1 degree C for scanning for 15 minutes)-standard aorto-uni-iliac stent grafts (fast turnaround time - delivery up to 48 hours from the date of order) -diameter of the aortic part of the stent graft 23-36 mm, diameter of the iliac part 10-28 mm - both bifurcated and aorto-uni-iliac versions -possibility to use the stent graft to supply wide, highly convoluted aneurysm necks (ie. aortic diameter of 31-32 mm with a renal bend of 65-75 degrees)-possibility to use the stent graft to deliver aneurysms with a neck length of 10 mm (according to the user's instructions)-insertion system with a diameter not exceeding 20F for the main parts of the stent graft and 16F for the iliac parts (contralateral legs)-hydrophilic covering of the insertion system -available shunts for stent grafts with diameters of 18, 20, 22, 24, 26F-complete with two 260 cm superrigid guidewires and a stent graft shaping balloon of capacity. 60ml with the possibility of tightening to 46 mm - in case of ordering aorto-uni-iliac stentgraft - in the standard available occluders for the iliac artery with a diameter of 8-24 mm -possibility of conversion to a stentgraft for the thoracic aorta with a diameter of 22-46 mm - with an insertion system max. 25F for all diameters -the price offered is to be for the entire set of components needed to supply an aneurysm/dilatation in the abdominal or thoracic segment during a single procedure set 50 1 System for removal of foreign bodies from blood vessels: -includes: loop, torc, introducer and catheter, -size 6F - 7F -working range: 6-45 mm, -loop length 120 cm -catheter length 100 cm -system consisting of three nitinol loops -system that also allows repositioning of venous catheters and clearing of fibrin-coated venous catheters; high flexibility, transfer of rotation 1:1; -loops with fused platinum fibers for excellent scopic visibility -catheter made of FEP (Teflon) resistant to kinking and kinking with tip bent 15 degrees to allow control of the system pcs 20 1 Endovascular kit, mechanical vascular thrombectomy -enabling detachment, aspiration, fragmentation and removal of thrombus from the vessel -external size of the probe 6F -11F -working length 70cm -140cm -performance 0.5 cm/sec - 1.5cm/sec -aspiration 0.5ml/sec - 1.5ml/sec -speed 30000 to 60000 rpm -operating on 0.018" guidewire to 0.032" -designed for small vessels and medium vessels -magnetically transferred drive -activation of probe operation by foot (special pedal) and manually -possibility of reverse drive pcs 352 One probe drive lease for the duration of the contract m-c 12 1 Threads made of PTFE without memory effect caused by confectioning for prosthesis anastomosis with PTFE with needle to thread ratio 1:1: -knot strength for thickness 6/0 0.65 kg -knot strength for thickness 5/0 1.00 kg -needle 3/8 circle -needle length 9 mm and thread length 76 cm -needle length 13 mm and thread length 91 cmPack = 12 sachets op 6 1 Treatment guide: -constructed of nitinol core, coated with PTFE and slippery hydrophilic coating, -standard stiffness guides, length.180 cm with diameters of 0.018'' with a conical tip length of 30 mm straight and bent; -guide available with a gold radiomarker in the distal part, with a soft conical tip of 50 mm and 80 mm bent at an angle of 45 or 70 degrees pcs. 252 Treatment guidewire: -constructed of nitinol core, coated with PTFE and slippery hydrophilic coating -guidewires long, standard stiffness with diameter 0.035", 260 cm, with conical tip 10 and 30 mm pcs 1003 Treatment guidewire: -constructed of nitinol core, coated with PTFE and slippery hydrophilic coating -guidewires with standard stiffness, length 180 cm with diameters of 0.035'', with tapered tip -lengths 10, 30, 50, 80 mm pcs. 3504 Interventional guidewires, hybrid-guidewire with hybrid structure in the proximal part coated with PTFE and distal part coated hydrophilically with polyurethane containing tungsten-length of hydrophilic coating in the distal part 25 cm-proximal part of the guidewire extra rigid with nitinol or steel core-distal part of the guidewire with nitinol core-distal tip of the guidewire bent or straight-available diameters 0,035", 0.014", 0.018"-lengths 18, 260 and 300 cmpcs. 4005 Reinforced vascular sheath /guidewire/ with marker on spike with hydrophilic coating, for crossover, difficult arterial exits -sheath with diameter of 5 - 8 Fr -compatible with 0.038" guidewire. -large inner diameter: 0.076" (1.93 mm) for 5 Fr 0.087" (2.20 mm) for 6 Fr 0.100" (2.54 mm) for 7 Fr 0.114" (2.90 mm) for 8 Fr -hydrophilic coating on 5, 15 or 35cm distal -reinforced with steel braid -high resistance to bending and kinking of longitudinal structure, no lumen ovalization at the bend -whole sheath clearly visible under scopy -gold marker 5 mm from the distal end -atraumatic, smooth transition between sheath and dilator and tapered tip of dilator -lateral arm, at the distal end of the lateral arm a one-way valve and a three-way faucet to allow flushing of the sheath or administration of the drug and to ensure tightness, intuitive switching of the faucet into one of three possible positions -perceptible, characteristic click -silicone hemostatic cross-valve at the proximal end funnel-shaped cross-section of the proximal end of the sheath (just behind the valve) -length 45 cm, 65cm pcs. 1006 Carotid stent to prevent microembolization of cerebral vessels (...) pcs. 157 Vascular access site closure kit (...) pcs. 5008 Supporting catheter (...) pcs. 209 Guiding shirt, with marker, reinforced, 90 cm long (...) pcs. 10Due to the limited number of characters, the detailed description of the subject of the order for items. 6-9 can be found in the Order Specification 1 PTFE vascular prosthesis with a two-layer wall structure, equipped with a steel tip for easy attachment to the tunnelizer (GDS) or without, sterile 5 years from the date of manufacture; porosity: outer layer 60 µm, inner layer 60/20 µm. Standard wall thickness (0.58 mm), seam pullout resistance 6.49 N, radial tensile strength 498 N; water entry pressure 266 mmHg. Ability to be re-sterilized once when an accidental opening of the prosthesis occurs, confirmed by standards in the instructions for use. Also designed for arteriovenous fistulae A Reinforced externally spiral 1.A with GDS, reinforced, spiral, externally, removable reinforcement 6mm x 40cm pcs 52.A with GDS, reinforced, spiral, externally, removable reinforcement 8mm x 50cm pcs 53.A with GDS, reinforced, spirally, externally, with removable reinforcement 6mm x 70cm pcs 54.A with GDS, reinforced, spirally, externally, with removable reinforcement 8mm x 70cm pcs 5B With flange possible to cut at any angle pcs 1.B with GDS, with flange 6mm x 80cm pcs 2C Tapered pcs 1.C with GDS, unreinforced 4/6mm x 45cm pcs 52.C with GDS, reinforced peelable 4/6 mm x 45 cm pcs 5 Straight and bifurcated sealed dacron vascular prostheses A Straight knitted vascular prosthesis, one side external velour sealed with collagen,with additional inverted weave, wall thickness 0.49 mm, permeability ≤5ml/cm2/min, no preconditioning required in sizes:1A Diameter 6 mm, prosthesis length 40-70 cm pcs 102A Diameter 8 mm, prosthesis length 40-70 cm pcs 103A Diameter 16 mm, prosthesis length 15-20 cm pcs 24A Diameter 18 mm, prosthesis length 15-20 cm pcs 25A Diameter 20 mm, prosthesis length 15-20 cm pcs 26A Diameter 24 mm, length of prosthesis 15-20 cm pcs 2B Straight knitted vascular prosthesis, one side external velour sealed with collagen,with additional inverted weave, wall thickness 0.49 mm, permeability ≤ 5ml/cm2/min, antimicrobial, impregnated with silver salts, no preconditioning necessary in sizes:1B Diameter 6 mm, length of prosthesis 40 cm pcs 102B Diameter 6 mm, length of prosthesis 70 cm pcs 153B Diameter 8 mm, length of prosthesis 40 cm pcs 84B Diameter 8 mm, length of prosthesis 70 cm pcs 2C Knitted vascular prostheses forked on one side externally velour sealed with collagen, with additional inverted weave, wall thickness 0.49 mm, permeability ≤ 5ml/cm2/min, no preconditioning required, in sizes:1C Diameter 14/7 mm, prosthesis length 40-50 cm pcs 52C Diameter 16/8 mm, prosthesis length 40-50 cm pcs 53C Diameter 18/9 mm, prosthesis length 40-50 cm pcs 54C Diameter 20/10 mm, prosthesis length 40-50 cm pcs 55C Diameter 22/11 mm, prosthesis length 40-50 cm pcs 106C Diameter 24/12 mm, length of prosthesis 40-50 cm pcs 5D Knitted vascular prosthesis bifurcated, unilateral external velour sealed with collagen, additional inverted weave, wall thickness 0.49mm, permeability ≤ 5ml/cm2/min, Anti-bacterial, impregnated with silver salts, no preconditioning required in sizes:1D Diameter 16/8 mm, length of prosthesis 50 cm pcs 22D Diameter 18/9 mm, length of prosthesis 50 cm pcs 23D Diameter 20/10 mm, length of prosthesis 50 cm pcs 24D Diameter 22/11 mm, length of prosthesis 50 cm pcs 2 Knitted vascular patches, sealed with collagen, permeability ≤ 5ml/cm2/min; with marker, thickness 0.41mm in sizes:1 14 mm x 75 mm pcs 202 6 mm x 75 mm pcs 203 8 mm x 120 mm pcs 15 1 PTFE vascular prosthesis with a three-layer wall structure for arteriovenous fistulas, equipped with a steel tip for easy attachment to the tunnelizer (Slider GDS), sterile 5 years from the date of manufacture; With standard wall thickness and variable wall thickness over a 7 cm section on each side of the prosthesis; variable wall thickness 1.1 mm section for cannulation / 0.8 mm section for anastomosis; porosity: outer layer 60 µm, protective membrane < 5 µm, inner layer 60/20 µm, suture pullout resistance 16 N, radial tensile strength 750 N; water entry pressure 300 mmHg. Ability to re-sterilize once when accidental opening or damage to the prosthesis package occurs, confirmed by standards in the instructions for use. Ability to quickly puncture the prosthesis1a with two GDS, with variable wall thickness, tapered 4/6 mm x 45 cm pcs 22b with two GDS, with variable wall thickness, tapered 4/7 mm x 45 cm pcs 22 Vascular prosthesis made of PTFE-with a three-layer wall structure-equipped with a steel tip for easy attachment to the tunnellizer-variable wall thickness 1.1mm /0.8mm-porosity : outer layer 60 μm, protective membrane <5 μm, inner layer 60/20 μm-suture pullout resistance 16N, radial tensile strength 750N-water entry pressure 300 mm Hg-possible to puncture in the first 24 hours2a Straight dia. 6, 7 mm useful length 30 cm pcs 12b Dissected dia. 4-6, 4-7 mm useful length 35cm pcs 12c Tapered dia. 4-6, 4-7 mm useful length 35cm pcs 1 1 Stapled dia. usable 35cm pcs 1 1 PTFE-coated steel stents, laser-cut, coated on both sides, inside and outside with PTFE, including the ends of the stent, PTFE porosity 100-120µm for better biocompatibility pre-mounted on a balloon, 5, 6, 7 mm with the possibility of tightening and cloaking the stent for better accommodation to the anatomy and the diameter of the blood vessel up to 8 mm-2 gold markers -length of the stent: 16, 22, 38, 59 mm -system length: 80 and 140 cm -compatible with 0.035" guidewire -OTW system -low passage profile, compatible with shir: 6 FR for sizes 5 x 16.22 and 6 x 16.22 and 7 FR for others -compatible with 8 FR guiding catheter for 5 and 6 mm and 9 FR for 7 mm -nominal pressure 8 ATM -average burst pressure 12 ATM pcs. 102 PTFE-coated steel stents, laser-cut, coated on both sides, inside and outside with PTFE, including the ends of the stent, PTFE porosity of 100-160µm for better biocompatibility pre-mounted on a balloon, 12mm with the possibility of tightening and cloaking the stent for better accommodation to the anatomy and the diameter of the blood vessel up to 22mm. -2 gold markers -length of stent: 29, 41, 61 mm -system length: 80 and 120 cm -for 0.035 guidewire -OTW system -compatible with 9FR sheath -nominal pressure 12 ATM -average burst pressure 12 ATMpcs 53 Knitted, polyester vascular patches, sealed with animal collagen with additional inverted weave, impregnated with silver salts; permeability <5ml/cm2/min, wall thickness 0.41 mm, width from 10 to 14 mm, length from 75 to 150 mm pcs. 20 1 Atherectomy and thrombectomy system compatible with JetStream atherectomy console on the Hospital's equipment 2a Atherectomy catheter 2.4/3.4 -set, consisting of: catheter, catheter control unit, pump cartridge, spiked drain, collection bag -catheter that allows atherectomy and active mechanical thrombectomy to be performed with saline -catheter working head equipped with folding wings to enlarge the working diameter of the catheter if necessary -catheter working length 120 cm -over the wire catheter -compatible with 0.014" guidewire -compatible with 7F sheath -catheter profile 2.5mm -working head diameter: 2.4mm with wings folded and 3.4mm with wings unfolded -minimum vessel diameter required for the procedure: 3.5mm with folded wings and 4.5mm with unfolded wings pcs 352b Atherectomy catheter 2.1/3.0-kit, consisting of: catheter, catheter control unit, pump cartridge, spiked drain, collection bag -catheter allowing atherectomy and active mechanical thrombectomy with saline -catheter working head equipped with folded wings to enlarge the working diameter of the catheter if necessary -catheter working length 135 cm -catheter over the wire -compatible with guidewire 0,014"-compatible with 7F sheath -catheter profile 2.5mm -working head diameter: 2.1mm with folded wings and 3.0mm with unfolded wings -minimum vessel diameter required for the procedure: 3.0mm with the wings folded and 4.0mm with the wings unfolded 2c Atherectomy catheter 1.6-kit which includes: catheter, catheter control unit, pump cartridge, spiked drain, collection bag- catheter that allows atherectomy and active mechanical thrombectomy with saline- catheter working length 145 cm- catheter over the wire-compatible with guidewire 0,014"-compatible with 7F sheath-catheter profile 2.33mm-working head diameter 1.6mm-minimum vessel diameter required for the procedure 2.5mm 2d Atherectomy catheter 1.85-kit which includes: catheter, catheter control unit, pump cartridge, spiked drain, collection bag -catheter that allows atherectomy and active mechanical thrombectomy with saline -catheter working length 145 cm -catheter over the wire -compatible with guidewire 0,014"-compatible with 7F sheath -catheter profile 2.33mm -working head diameter 1.85mm -minimum vessel diameter necessary for the procedure 2.75mm 3 Catheter guidewire High-specialty guidewires 0.014" i 0.018". Lengths: 130, 190 and 300 cm Guidewire tip: straight - shaped or bent ''J''. Distal section covered with silicone, proximal section covered with TeflonThe guidewire with graded gradation of tip taper: 5/7/10 cm for 0.014" guidewire and 2.5/3/7 cm for 0.018" guidewire. Available with shading markers at 5 mm intervals on the distal end pcs. stent with two markers integrated into the stent and two on the balloon -available stent diameters from 6mm to 10mm -available stent lengths from 19mm to 59mm -zero shortening of the stent at expansion -high radial strength of the stent -compatible with 6F sleeve -compatible with 0,035" -available in two stent lengths: 75cm and 135cm pcs. 20 1 Balloon-expandable, chromium-cobalt stents, compatible with 0.035" guidewire for the treatment of bidor arteriesPassive coating of silicon carbide -does not activate platelets and fibrinogen (reduces the risk of clotting on the surface of struts), reduces the diffusion of metal ions into the surrounding tissue (reduces the risk of corrosion and sensitization to nickel) and accelerates the process of endothelialization and healing of the vessel-Material of construction: chromium-cobalt alloy-thin-walled stent-lengths 18, 28, 38, 58, 78 mm-diameters 5.0, 6.0, 7.0, 8.0, 9.0, 10.0 mm-lengths of delivery systems 90 cm, 130 cm, and 170 cm (radial access possible)-Over The Wire-2 markers on delivery system indicating stent position-compatible with 6F introducer for all diameters-shaft 5.1 - 5.4 F, hydrophobically coated, dual-lumen-nominal pressure 10 atm-RBP 14 atm (for diameters 5 - 8 mm) and 12 atm (for diameters 9 - 10 mm)-stent strut thickness 110 µm for diameters 5 - 7 mm and 140 µm for diameters 8 - 10 mm,-radial force: 0.128 N/mm2-possibility to upstent 5 mm diameter to 7.5 mm-double helix design allows proper apposition of the stent to the vessel wall and its proper support and prevents overlapping and protrusion of the stent wires-preventing the "fish scale" effect-with a high elasticity-bending force of 57.4 Nmm2-negligible shortening pcs 702 Reinforced Introducer-length: 45 cm (factory bent-cross over and straight)-polymer construction with steel reinforcement to ensure retention of inner diameter-diameter 4, 5, 6 F-compatible with 0.035 "guidewire-fabrically taped-hemostatic valve and three-way stopcock-rewindable tap in 5 and 6F shunts-introducer inner diameter 4F - 0,064" pcs 503 Reinforced Introducer-90cm (straight)-Polymer construction with steel reinforcement to maintain inner diameter-Diameter 4, 5, 6,7, 8F-Hydrophobic coating on distal 30 cm. for diameters 5 - 8F for ease of passage and stabilization-compatible with 0.035 "guidewire-fabrically tapered-hemostatic valve and three-way tap-rewindable tap in 5, 6, 7, 8F-introducer inner diameter 4F - 0.064 "pcs 104 Reinforced Introducer (....) pcs 105 Balloon catheters compatible with 0.014 guidewire (...) pcs 106 Balloon catheters compatible with 0.018" guidewire (...) pcs 207 Balloon catheters compatible with 0.035" guidewire. (...) pcs 308 Long self-expanding stents compatible with 0.018" guidewire. (...) pcs 209 Balloon-expandable renal stents compatible with 0.014" guidewire (...) pcs 410 Drug-eluting balloon catheters compatible with 0.018" guidewire (...) pcs 511 Extra Support Catheter (Designed for replacement and support of guidewires in peripheral vessels) (...) pcs 5Due to the limited number of characters, the detailed description of the subject of the order for items. 4-11 can be found in the Order Specification 1 Stengraft for abdominal aorta with shirt system with the following characteristics:-the stent is constructed on the basis of a steel Z-stent and interchangeably nitinol, giving the individual segments optimal expansion force with high radial strength-it has a polyester covering made of fabric used for the production of vascular prostheses-it has suprarenal fixation by means of a free segment equipped with spikes to ensure permanent placement of the stent graft in the neck of the aneurysm and with ties that allow controlled release of the proximal and distal parts of the stent graft-it is offered in sizes: main element: 22, 24, 26, 28, 30, 32 and 36 mm, leg size: 9, 11, 13, 16, 20, 24 mm-it is supplied loaded into an insertion system with a body diameter of 18-22 F for steel stent grafts and 16-17F for nitinol stent grafts, and legs: 14 and 16F (for steel stent grafts); 12 and 14F (for nitinol stent grafts)-introducer equipped with dilator and reinforced vascular sheath being an integral part of the set equipped with the so-called "shutter" valve. shutter set 302 Stentgraft for the thoracic aorta with a shirt system one or two-part, has a polyester covering made of fabric used in the production of vascular prostheses, built on the basis of a steel Z-stent and interchangeably nitinol with the following characteristics:-the proximal element has fixation spikes on the upper part-the distal part has a lower end with fixation spikes-steel version available modified with an uncovered stent of 36 and 46mm in diameter and up to 185mm in length as an adjunct to covered elements for the treatment of bifurcations-available dimensions: 22 to 42mm in diameter for steel stent grafts and 24 to 46mm in diameter for nitinol stent grafts-available lengths up to 218mm for the steel version and 233mm for the nitinol version-the system has an introducer with the possibility of controlled release of the distal as well as proximal part with safety wires pcs 23 Stent graft for the supply of common iliac artery aneurysm in abdominal aortic aneurysm surgery:-constructed on the basis of a steel Z-stent, polyester covering- main part, bifurcated with diameters: 12 [mm] (proximally) and 10 and 12 [mm] (distally) length of the bifurcated part - common iliac artery section: 45, 61 [mm] length of the bifurcated part - section of the internal iliac artery: 41, 58 [mm]-delivered loaded on a precision introducer equipped with safety and release ties, together with one coated stent, and the necessary for implantation: loop, shunts, catheters and guidewires pcs 2 1 Drug-coated peripheral self-expandable stents:-nitrile coated with antiproliferative drug (paclitaxel)-not containing polymer -markers on the stent and on the introducer system -diameter 5-10 mm , length. 40-120 mm -diameter of insertion system 6F pcs 502 Self-expandable stents 0.035":-made of nitinol -laser-cut from nitinol tubing -high radial strength and flexibility -8 gold markers -horizontal connectors and Z-type design prevents shortening after release -one-stage delivery system and Flexor insertion catheter with coil tip provide resistance to bending -available sizes: diameter 5-14 mm; length 10 -20cm -shaft length 80 or125 cm -stents 12-14mm diameter length 40, 60, 80mmpcs 703 Hydrophilic guidewires: -diameter 0.018";0.025"; 0.035"; 0.038"-shaft length 145, 150, 180, 260, 320 cm-flexible atraumatic tip of 3 cm-long-coated with hydrophilic substance-good visibility in scopy-straight or J-shaped tip-available in rigid, semi-rigid and standard versions-additional device to facilitate guidewire maneuvering during use pcs 104 Rigid peripheral guidewire-steel guidewires with stiffened core and Teflon braid-available in different rigidity types: Amplatz, Lunderquist -diameters 0.025; 0.035; 0.038"-lengths 145, 180, 260, 300cm -atraumatic tempered tip of the guidewire core of different lengths from 3 to 16 cm pcs 205 Angiographic diagnostic catheter for specialized procedures-diameter 5F-sheath made of nylon, flexible, eliminates the risk of fracture, preserves the atraumatic nature of the tip-reinforced along its entire length with eight stainless steel wires for torque control- atraumatic catheter tip for very good visualization in x-ray images- controllability 1:1- designed for difficult and atypical anatomies- multiple tip shaping configurations (no less than 35: m.KMP, Vanschie 1-5; VS1-2; VSC 1,2,3LEV 1,2; MPB, among others)-catheters in the length range of 40-125 cm; compatible with 0.035" or 0.038" guidewires pcs 106 Reinforced booster catheters for CTO unblocking: -OTW catheter compatible with 0.014, 0.018", 0.035 "guidewires-Length. catheters 65,90,135,150 cm-straight and angled-shaft polymer tip with stainless steel braid for exceptional pushability-embedded 4 shadow markers in distal portion of catheter to allow sizing of vessel sections, hydrophilic coverage of distal 40 cm-catheters in 2.3F, 2.6Fi 4,0Fpcs 10 1 Self-expandable stent for femoral and popliteal artery (P1, P2, P3) laser-cut from a single piece of nitinol-helical design of the stent providing thanks to the high radial force -dynamic adaptation to the curvature of the vessel without changing the diameter of the stent -shell 6F -insertion system lengths 80cm and 130cm -internal channel diameter for the guidewire 0.035". -stent diameters from 5 to 7mm -stent lengths from 20mm to 170mm -six tantalum markers on each side of the stent for X-ray visibility -minimal stent shortening after expansion -multifunctional stent release system (one hand) pcs 502 Self-expandable stent for femoral and popliteal artery (P1, P2, P3) laser-cut from a single piece of nitinol -helical stent design for high radial force -dynamic adaptation to vessel curvature without changing stent diameter -6F cap -insertion system lengths of 100cm and 135cm -internal channel diameter for guidewire 0.035" -stent diameters from 6 to 7mm -stent lengths from 200 to 250mm -six tantalum markers on each side of the stent for X-ray visibility -minimal shortening of the stent after expansion -multifunctional stent release system (one hand) pcs 303 Self-expandable covered peripheral arterial stent graft; used in the exclusion of peripheral arterial stents; for vessel perforation; for vessel wall dissection, after atherosclerotic plaque dissection and vessel obstruction after balloon angioplasty, restenosis or reocclusion, for arteries, especially iliac arteries due to radial force-a nitinol stent embedded in ePTFE material between two layers (fused)-available diameters 5mm, 6mm, 7mm, 8mm, 9mm, 10mm, 12mm; 13.5mm, stent graft lengths in diameters from 5-8mm are 20, 30, 40, 60, 80, 100, 120mm, stent graft lengths in diameters 9-13.5mm are 30, 40, 60, 80, 100, 120mm-length of insertion system 80cm and 117cm-compatible with guidewire 0,035"-tantalum markers at the ends, improving visibility in X-ray (radio shadowing markers)-internal surface of the stent graft impregnated with carbon, recommended casing, respectively: 8Fr, 9Fr, 10Fr pcs 204 Balloon-expandable covered peripheral stent graft for the treatment of atherosclerotic lesions in the common and external iliac arteries -stent made of 316L stainless steel sandwiched between two layers of e PTFE-compatible with 0.035 "guidewire -non OTW balloon -insertion system 80 and 135cm-available diameters: 5,6,7,8,9,10 and 12mm-Available lengths: 16mm, 26mm, 37mm, 58mm (depending on diameter)-compatible with 6, 7, 8F sheath (depending on diameter)-nominal pressure for all diameters 8 atm-RBP for all diameters 12 atm pcs 155 Self-expanding stent for iliac arteries-self-expanding stent, nitinol-expandable, OTW system, compatible with 0.035'guidewire-6F sheath-diameter of stents 7, 8, 9, 10 mm-available in lengths: 20, 30, 40, 60, 80, 100 mm and an insertion system length of 80cm-on both sides of the stent 4 tantalum markerseszt 10 1 Peripheral embolization spirals: -stainless steel and platinum embolization spirals -covered along the entire length with synthetic fibers increasing the coagulation surface -compatible with catheter for lumen diameter 0.018"; 0.035"-conical and helical shape -releasable by pushing with a guide and detachable -possibility of releasing from narrower or wider end -various combinations of diameters and lengths (length from 1-5 cm, diameter from 2 - 15 mm), conical (dia. in the proximal part after release from 3 - 10 mm, in the distal part after release 2-5 mm) pcs 502 Stents with aortic-iliac occlusion - set.The set includes: 1 aortic stent graft and 2 peripheral stent grafts, including:2A Balloon-expandable aortic stent graft: cobalt-chromium (L605) ePTFE-coated-medium 12, 14, 16 mm; lengths. 19, 29, 39, 49, 59 mm (for 12 and 14 mm dia.) and 19, 29, 38, 48, 58 mm (for 16 mm dia.); Shaft length 75 and 120 cm; compatible with 9F (12 mm dia.) and 11F (dia. 14, 18mm)-shafts 18, 20, 22, 24 mm; shaft lengths 29, 38, 49 mm (sh. 18mm), 27, 37, 48 (sh. 20mm) and 37, 49 mm (sh. 22 and 24 mm); compatible with 14F shirting; shaft length. shaft 120 cm pcs 252B Balloon-expandable peripheral stent graft: cobalt-chromium (L605) ePTFE-coated balloon-mounted; diam. 5, 6, 7, 8, 9, 10 mm-stent lengths: 18, 22, 28, 38, 58 mm (for diameters 5 and 6 mm), 18, 23, 27, 37, 57 (for diameter 7) and 27, 37, 57 (for diameters 8, 9, 10 mm)-compatible with 6F sheath for all diameters 5, 6, 7, 8 mm and 7F for all diameters 9, 10 mm, compatible with 0.035"-shaft length. shaft 75 and 120 cm pcs 503 Shirt for insertion system pcs 404 Multipurpose vascular shunts with flexor technology-straight or with ANL1 curvature, including shunts dedicated to carotid arteries made of PTFE-reinforced spiral braid, with hydrophilic coating and RB shadowing band in the distal part of the shunt, with dilators in standard or high-flex version-available diameters: 4-12F length 45-110cm and large-diameter unreinforced vascular shunts made of kink-resistant flexible propylene (FEP) with a shadowy RB band in the distal part of the shirt and Check-Flo type hemostatic valve, with dilator included - available diameters 10-18F, length in the range 30-85cm pcs 20 Hemodialysis set 1 Permanent dialysis set (short,permanent catheters) - set including double-lumen catheter - inlet shape curved tip; Length measured as a distance from muff to tip (Cuff to tip), Packed individually pcs 402 Permanent dialysis set (femoral,permanent catheters) - set including double-lumen catheter - inlet shape curved tip; Length measured as a distance from muff to tip (Cuff to tip), Packed individually pcs 40 1 Balloon-expandable stent:-cobalt-chromium sloted tube stent-compatible with 0.035"-stent wall thickness no greater than 0.063"-length. insertion system 80 and 135 cm -available diameters from 4.0 to 10.0 mm -available stent lengths from 12 to 59 mm -all sizes compatible with 6F introducer -stent indicated for the treatment of newly formed or restenotic atherosclerotic stenosis and for the palliative treatment of stenosis caused by tumor infiltration in the biliary tract pcs 402 Self-expandable, Flexible closed-cell stent made of 6 pairs of nitinol fibers woven helically in a closed-cell geometry.Indications: popliteal and superficial femoral artery.-.sizes: diameter 4, 5, 6 and 7mm, stent length 40 - 200mm (at least 10 different lengths, including short stent of 20mm and long stent of 180 and 200mm)-catheter length 80 and 120cm-compatible with 6F and 0.018 guidewire-high resistance to:a).bending and stretching confirmed by endurance tests (10 million cycles without failure)b).torsion confirmed by mechanical tests (20 million cycles without failure)-implantation technology allowing to adjust the length and packing of the stent in the artery-possibility to model the stent after implantation-high radial strength-requires predilatationSizing of the stent 1:1 relative to vessel diameter pcs 203 Cobalt-chromium renal balloon stents, RX system -length of stent from 12 to 18 mm -diameters from 4.0 to 7 mm in 0.5 mm increments -low stent profile RBP pressure 14 atm -compatible with 0.014" guidewires -high radial force -compatible with 5 F introducer for all sizes pcs 44 Arterial and venous closure systems -suture systems for vessel closure after shirting in the range of 5-24 F, no polymeric material pcs 2005 Everolimus-coated balloon stent, L605 Cobalt Chromium -system length 145cm-guide 0.014"-mid. stent 2-4mm, length 8-48mmpcs 206 Ocluder type amplatzer-construction based on nitinol mesh, multilayer, ensuring self-expansion of the device in the vessel-available min. 3 types of vascular plugs of different design to choose from-diameter of the plug ranging from 3 mm to 22 mm-max. length of insertion catheter 100cm-diameter of insertion catheter 4-9F (0.038"-0,098") depending on the size of the plug-possibility to reposition the plug multiple times before final detachment from the delivery system-short embolization time after plug implantation-minimal risk of vessel recanalization after vascular plug application-commissioning allowing a large selection of sizes pcs 57 Multi-Purpose balloon catheter-compatible with 0.035"-available diameters from 3.0 to 14mm-available lengths: 20-40mm for 3.0mm diameter; 20- 200mm for 4.0 to 7.0mm diameters and 20- 80mm for 8 - 14mm diameters, in addition, for 4.0; 5.0 and 6.0mm diameters, length available. 250mm-length of insertion system 80 and 135cm-possible to use introdural 5F for diameters 3-6mm, 6F for diameters 7-12mm and 7F for diameter 14mm- NP 4-8atm RBP > 7atm, and for diameters 3.0 > 27atm , for size 4/60mm = 18atm-coverage for easy maneuverability in narrow and tortuous vessels-balloon material resistant to scratching and damage when passing through calcified tight lesions pcs 208 Steel vascular guidewire with hydrophilic and hydrophobic coating-guidewire diameters: 0.014", 0.018", 0.035"-guide lengths: 145 cm, 190 cm, 195 cm and 300 cm-available "J" type, straight and tapered guidewire tips, operator shapeable tip, nitinol or steel-guidewires with tip stiffness in the range: 1.5 g - 30.0 g - 0.035" guidewire with soft tapered to a diameter of 0.025" tip with a length of 17 cm pcs 60 1 Aspiration catheter -lengths 50/85/115cm: distal outer diameter-8F; 8F-available in straight and 2 curved tip variants-high pressure tubing included pcs 22 Aspiration catheter-length 135cm: distal outer diameter-6F-straight tip; high pressure tubing included pcs 23 Separator-separator for thrombectomy: thrombectomy assist devices-compatible with catheters pcs 64 Aspiration catheter-length 150cm; distal diameter 3.4F (end 30cm)-distal section covered with hydrophilic layer (75cm) pcs 25 Reservoir-calibrated, transparent reservoir-compatible with aspiration pump-volume 1000ml; equipped with filters to protect the pump from biological material pcs 66 PumpOil-free vacuum pump, illuminated place for aspiration reservoir; max. possible aspiration vacuum -29.2 inHg; 4-stage led suction force indicator; compatible with 1000ml reservoir with aspirated thrombus capture element (plastic mesh); integral part of thromboaspiration system RENTAL m-c 12 1 Kit for lithotripsy-balloon for calcification removal in sizes 3.5 to 8.0 for total balloon length 60mm (available balloons for btk in sizes 2.5-4.0mm for a total balloon length of 40mm)-Kit compatible with 0.014 "guidewire-Kit compatible with 5F, 6F introducer, 7F depending on balloon size-working length 135cm and 138cm depending on balloon size pcs 52 Lease of lithotripsy console m-c 12 1 Atherectomy system based on frontal cutting element and Archimedes screw-system for atherectomy equipped with frontal cutting blade and Archimedes screw, available system diameters: 1.5mm; 1.8mm; 2.2mm and 2.4mm-compatible with dedicated 0.014 "guidewires-the disposable handpiece system includes a battery-powered motor, achieves a rated speed of up to 12,000 rpm for a continuous run time of 20 minutes-a system with an outside diameter of 1.5 mm is indicated for use in vessels with a diameter of 2.0 mm or greater-a 1.8 mm system is intended for use in vessels with a diameter of 2.5 mm or larger-for vessels with a diameter of 3.0 mm or larger, the 2.2 mm and 2.4 mm system is indicated pcs 51A 0.014", 300cm guidewire dedicated to the system indicated in point 1 (package of 5 pcs) pcs 52 Intravascular ultrasoundElectronic ultrasound transducer with a resolution of 10 MHz to 20 MHz , in the form of a catheter with a working length of min. 90 cm to max 150 cm (±5cm), Ability to enter the vessel lumen with a catheter of min. 5F (inner diameter 0.56") and a guidewire with a minimum diameter of 0.014", Different imaging diameters of 20mm, 24mm, 60mm available, Catheter does not require pre-preparation for examination (plug & play system) pcs 502A Monthly lease of IVUS mobile console with color screen, with ChromaFlo option, compatible with electoronic probes with imaging range of 20mm, 24mm, 60mm. 240V power supply m-c 12

Opportunity closing date
02 August 2023
Value of contract
to be confirmed

About the buyer

Address
Szpital Specjalistyczny im. Edmunda Biernackiego ul. Żeromskiego 22 Mielec 39-300 Poland
Contact
przetargi@szpital.mielec.pl

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?