United States - 65--walk-in cooler/freezer
For more information and to make a bid you will need to go to the third party website.
Details
Provided by- Opportunity closing date
- 24 July 2019
- Opportunity publication date
- 22 July 2019
- Value of contract
- to be confirmed
- Your guide to exporting
Description
Added: Jul 19, 2019 11:10 am
This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time.
This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine the following:
The interest and capability of small business, especially service disabled veteran owned small business and veteran owned small business;
Whether the business source is a manufacturer or authorized distributor, verified by an authorization letter from the original equipment manufacturer;
Located in the state of Indiana, preferably Northern Indiana, and
Size classification relative to the North American Industry Classification System (NAICS) code 333415 for the proposed acquisition.
The VA Northern Indiana Healthcare System, Network Contracting Office 10, is seeking potential sources, for a Walk-In Refrigerator and Walk-In Four Compartment Cooler/Freezer at its Fort Wayne Facility with the following specifications:
1. Walk-In Refrigerator
Walk-in 1 compartment cooler
Approximate size 15 ft 7 in x 11 ft 7 in
1 compartment with floor
Ceiling: Single Span
Panel Thickness: 4 inch exterior with 4 inch floor with 4 inch ceiling
At least 5 year Compressor Warranty
At least 5 year System Parts with 1 year Labor Warranty
Refrigeration range: -40 to 100 degrees F
Finishes: Stainless steel (22 Ga)
Structural Components:
Structurally reinforced insulated floor with interior ramp
Stainless steel (22 Ga)
Screws into regular VP base
10/L Stainless Steel (22 Ga) Capping for Ceiling
10/L Stainless Steel (22 Ga) Capping for Floor
2 notch Ceiling Panel
Doors/Openings:
1 insulated stainless steel hinged door
Interior and exterior kickplate
1 door window
1 stainless steel ramp
1 strip curtain
Lighting
4 48 LED lights
At least 1 vapor proof LED blub
Refrigeration:
BLP 214MA-S1B-TSV + 115/1/60 R404A
SmartVap + Air Defrost with EEV installed
1 BEZA 010 H8 HT3CB (208 230/3/60) w/ smart speed
Scroll Unit 12000 BTU
2. Walk-In Four Compartment Cooler/Freezer
Walk-in four compartment Cooler/Freezer with Floor
Approximate sizes
Walk in Cooler 1 compartment 12 ft 9 in x 17 ft 4 in
Walk--in Cooler 2 compartment 13 ft 8 in x 17 ft 4 in
Walk-in Freezer 1 compartment 15 ft 8 in x 17 ft 4 in
Walk-in Freezer 2 compartment 15 ft 8 in x 17 ft 4 in
Ceiling: Multi Span Self Supporting
Panel Thickness: 4 Exterior Vertical with 4 Partition, 4 Floor, 4 Ceiling
1260 S/F ½ Plywood Foamed in Panel
16 Notch Floor Panel
Pressure Relief Ports (<400 sq/ft)
Refrigeration range: -40 to 100 degrees F
At least 5 year Compressor Warranty
At least 5 year System Parts with 1 year Labor Warranty
Finishes: Stainless steel (22-26 Ga)
Doors/Openings:
4 Super Doors
1/8 D.T. Kickplate Interior and Exterior
4 Door Windows 4 each
3 Stainless Steel Ramps
4 Strip Curtains
Lighting
At least (21) 48 LED KEIL 48x754-CL-N Lights
Structural Components:
Structurally reinforced insulated floor with interior ramps
4 Vapor Proof LED Bulb
Screws into regular VP base
100 L/F Self Supporting 6 channel
166 L/F Stainless Steel (22 Ga.) Capping Ceiling
166 L/F Stainless Steel (22 Ga.) Capping Floor
16 Notch Floor Panel
16 Notch Ceiling Panel
20 S/F Stainless Steel (22 Ga)(Closure Metal)
100 S/F Stainless Steel (22 Ga)(Removable Closure)
Refrigeration:
2 BEZA 035 L8 HT3CC (208 230/3/60)
Must include: Suction Accumulator
1 BEZA 020 H8 HT3CB (208 230/3/60) w/ smart speed
Scroll Unit 18200 BTU
1 BEZA 025 H8 HT3CB (208 230/3/60) w/ smart speed
Scroll Unit 22700 BTU
1 BLP 320MA S1B TSV+ 115/1/60 R404A
SmartVap+ Air Defrost with EEV Installed
1 BLP 314LE S2B TSV+ 208 230/1/60 R404A
SmartVap+ Electric Defrost with EEV Installed
1 BLP 317LE S2B TSV+ 208 230/1/60 R404A
SmartVap+ Electric Defrost with EEV Installed
1 BLP 423MA S1B TSV+ 115/1/60 R404A
SmartVap+ Air Defrost with EEV Installed
Installation Requirements:
Contractor shall perform all installation services between the hours 5:30 AM and 7:00 PM, 7 Days a week.
Contractor shall provide 1 freezer truck and 1 cooler truck for current food on hand during installation.
Uncrate, new walk-ins and move into location of installation.
Removal and disposal of existing units, including freon from old equipment
Contractor shall remove and dispose old outdoor condensing units and install new units in the subbasement with new piping, erect the boxes, and hang coils. Run and insulate refrigeration lines through the ceiling to the subbasement.
Contractor shall reinstall suppression sprinkler and sprinkler heads and make all final electrical connections within 5 feet of termination points.
Erect the boxes, hang coils and set new condensers in sub-basement.
Core drill the floor to sub-basement. Run refrigeration lines Not to Exceed 20 feet each.
Insulate refrigeration line.
Make final electrical connections to proper sized utilities to within five feet of terminating points.
Contractor shall provide and install a temporary plastic wall in front of walk in coolers during demolition and installation to provide a barrier.
All contractors that are interested in meeting this requirement are asked to submit the following information:
Company Name
Company Address
DUNS Number
Company POC Name
Company POC Phone
Company POC Email
Business Size/Type under NAICS 333415
GSA Contract Number (if applicable)
Additional information:
All contractors must be registered with the System for Award Management (SAM) at https://www.sam.gov.
Any contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.102.
Any contractor that believes they are capable and desires to claim preference for veteran owned small business status must be registered with the Vendor Information Pages (VIP) at https://www.vip.vetbiz.gov as an SDVOSB or VOSB.
Responses due to Amanda Reid, Contracting Officer, by Wednesday, July 24, 2019, 10:00 a.m. est. time. Please e-mail all responses to Amanda.Reid1@va.gov, NO phone calls are being accepted.
- Opportunity closing date
- 24 July 2019
- Value of contract
- to be confirmed
About the buyer
- Address
- Department of Veterans Affairs Richard L. Roudebush Department of Veterans Affairs Medical Center United States
The deadline to apply for this opportunity has passed.
Visit the
opportunities page
to find another.