Description

Lot1, approx. masses:Waterproofing work:- 839 m2 bitumen primer,- 779 m2 waterproofing base slab, 1-layer, G 200 S4+AL.Check/accept preliminary services vapour barrier- 2 152 m2 levelling layer, vapour barrier PVE PV 200 S5, check and accept.Roof waterproofing works:- All-inclusive construction site equipment Lot 1,- 1 811 m2 emergency waterproofing as compensation and vapour barrier, bituminous sheet PYE PV 200 S5,- 1 365 m2 inclined insulation layer, multilayer, MW, hydrophobic, DAA, 2 %, D = i. M. 270 mm,- 139 m2 inclined insulation layer, multilayer, MW, hydrophobic, DAA, 2 %, D = i. M. 210 mm,- 56 m2 inclined insulation layer, multilayer, MW, hydrophobic, DAA, 2 %, D = i. M. 200 mm,- 53 m2 inclined insulation layer, multilayer, foam glass, 2 %, D = i. M. 326 mm, flushed into hot bitumen plus bitumen covering smear,- 1637 m2 roof waterproofing, 2-ply, bitumen welded membrane, lower layer: PYE G 200 S4, upper layer: PYE PV 200 S 5,- 215 m waterproofing attika, bitumen welded membrane G 200 S4, glued,- 12 pcs. Drain DN 50, system-bound, made of galvanised steel, with gravel trap, for flat roof, - 13 pcs. Emergency overflow DN 100, of galvanised steel drainage body, clamping flange for roof sealing membrane and gravel trap sieve as well as with spittoon, - 33 pcs. cast iron strand ventilator, DN 100, DN 80 and DN 125, - 1 637 m2 roll gravel layer, 16/32 mm, D = 50 mm; plus 120 m2 extra thickness for edge and corner areas,- 1 637 m2 separating and protective fleece, PES fleece, 300 g/m2,- 142 m gravel guard Aluminium profile 60/100 mm, overall height 80 mm,- 154 m Securant system with rope, for main and secondary roof,- 2 pcs. Protective equipment,- 73 m2 concrete pavement slabs, D = 50 mm, 500 x 500 mm, double-row, jointless laid,- 91 m2 building protective mat, rubber granulate D = 10 mm,- 60 m railing, made of hot-dip galvanised steel pipe, with railing base, upper and middle belt, with 2 external/internal corners and 2 wall connections.roof openings/light domes:- 1 pc. Smoke extraction from elevator shafts, as approved smoke and heat extraction system for an elevator shaft, approx. 65 x 65 cm, as fully functional SHEV system incl. cable plan, SV approval and commissioning.Plumbing:- 215 m plywood panels d = 22 mm, strip width up to 60 cm, as UK for horizontal parapet cladding,- 215 m parapet cover profile, aluminium sheet, multiple folded, RAL powder-coated, sheet thickness 3 mm, crown width approx. 640 mm, cut to size approx. 900 mm,- 138 m downpipe DN 50, as rainwater downpipe for pressure flow, galvanised steel pipe, installation hidden behind facade cladding,- 56 pcs. Elbows DN 50, galvanized steel pipe, 45o,- downpipe supports, connections roof outlet and ground pipes (each 12 pcs.). Trafficable flat roof, lot 2Quantities as approx.Information:- All-inclusive, construction site equipment Lot 2,- 341 m2 pre-treatment,- 341 m2 bitumen primer, cold workable,- 234 m2 levelling layer asphalt mastic, layer thickness approx. 25 mm, between steel plates on site,- 234 m2 levelling layer asphalt mastic, layer thickness approx. 10 mm, full-surface, - 53 m insulating wedges, foam glass, 80 x 80 mm, - 107 m2 gradient insulation, foam glass, type: DAA/dx, densely butted, full-surface and fully joint bonded in hot bitumen, thickness 220 mm, - 234 m2 gradient insulation, foam glass, type: DAA/dx, densely butted, full-surface and fully joint bonded in hot bitumen, thickness i. M. 170 mm,- 341 m2 Bitumen top coat of hot bitumen 100/25, full surface on foam glass surface,- 62 m thermal insulation, foam glass as above, 1-layer, height 50 cm to 100 cm, D = 60 mm, on rising components,- 341 m2 raw glass fleece, 2-layer, with seam and joint covering,- 341 m2 sealing 1. Layer, full surface with approx. 2-3 kg/m2 hot bitumen, e.g. 100/25, of polymer bitumen roof waterproofing membrane DU/E1 PYE-PV 200 DD,- 341 m2 Waterproofing 2nd layer, full surface with approx. 2-3 kg/m2 hot bitumen, e.g. 100/25, from polymer bitumen roof waterproofing membrane DO/E1 PYE-PV 200 DD,- 41 m2 waterproofing 1st layer, fully bonded, on rising components,- 41 m2 waterproofing 2nd layer, fully bonded, on rising components,- 41 m2 waterproofing 2nd layer, fully bonded, on rising components,- 41 m2 waterproofing 2nd layer, fully bonded, on rising components,- 41 m2 waterproofing 2nd layer, fully bonded, on rising components,- 41 m2 waterproofing 2nd layer, on rising components,- 41 m2 waterproofing 2nd layer, on rising components Layer, fully bonded, on rising building components,- 341 m2 PE foil, 0.2 mm, 2-ply, loose as plain bearing, with seam and butt overlap,- 341 m2 pressure distribution plate, in-situ concrete, C 20/25, D = 120 mm, normal concrete with sloped surface, n. stat. 400 kg reinforcing bar BSt IV 500S, for in-situ concrete components, all diameters, as cubic reinforcement, according to reinforcement plans of the structural engineer,- 1 700 kg reinforcing bar mesh BSt IV 500 M, bearing mats, for in-situ concrete components, according to reinforcement plans of the structural engineer,- 600 kg spacer BSt 500, according to reinforcement plans of the structural engineer,- 72 m edge formwork, H = 120 mm, for tr. -Pressure distribution plate as above,- 11 m edge angle made of stainless steel, side lengths 650 / 300 mm, t = 4 mm, mounted on reinforced concrete ceiling,- 8 m movement profile, watertight, resistant to heavy loads, for outdoor use, visible surface stainless steel, expansion insert EPDM, profile-H = 90 mm.joint width approx. 30 mm, visible width approx. 95 mm, joint clearance horizontal up to 40 mm, joint clearance vertical up to 20 mm- 341 m2 separating layer, raw glass fleece, with seam and joint overlap,- 55 m wall connection, aluminium clamping rail and permanently elastic sealing of the joint, fixing corrosion-resistant,- 341 m2 adhesive bridge, as primer asphalt-bearing top layer installation,- 341 m2 mastic asphalt, nominal thickness 60 mm, multi-layer, incl. grit scattering and thermoplastic welding as well as the grinding of the seams, - 126 m edge joints, with bituminous fusible wire, - 53 m pressure bar, approx. 30 x 50 mm, impregnated,- 53 m pressure and storage rails, t = 2 mm, aluminium, multiple edged, h = 150 mm, to protect the vertically raised sealing,- 6 corners to pressure and storage rails,- 15 m drainage channel as flat channel, polymer concrete, sole slope 0.5 %, load class C 250, cast iron cover, channel width 185 mm.incl. concrete bedding and back support.

Opportunity closing date
17 July 2019
Value of contract
to be confirmed

About the buyer

Address
Kliniken des Landkreises Neustadt Paracelsusstr. 30-36 Neustadt an der Aisch 91413 Germany
Contact
michael.merkel@kliniken-nea.de

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?