Italy - Miscellaneous medical devices and products

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
21 May 2019
Opportunity publication date
26 March 2019
Category
33190000, , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Value of contract
£1m-5m
Your guide to exporting
Report opportunity

Description

1)-1 "VENOSE CATHETERS for central cannulation at ONE LUMEa) catheter length: 15- 20- 30 cm; b) lumen: 14G -16 G -18 G annual requirement 8952)-1 "VENOSE CATHETERS for central cannulation at ONE LUMEa) catheter length: 15- 20- 30 cm;b) lumen: 14G -16 G -18 G Annual requirement 30 The lumen gauges must be declared in the technical data sheet" "VENOSE CATHETERS for central cannulation at TWO LUMIa) catheter length: cm 15- cm 20- cm 30b) lumen:16G/16G The lumen gauges must be declared in the technical sheet "ANNUAL NEED 1365 "VENOSI CATHETERS for central cannulation with TWO LUMS with antimicrobial treatment based on chlorhexidine/sulfadiazine silver on the outer surface of the catheter 7FRa) length of the catheter cm 20b) Required lumen: 16G /16G "ANNUAL NEED 475 "Venous catheters with antimicrobial bilume - free of chlorhexidine - for pediatric use 4 FR a) length of the catheter 10b cm) Required lamp: 22G /22G "ANNUAL NEED 115 "VENOSE CATheters for central cannulation to THREE LUMIa) length of the catheter: cm15 approx. and 20cm, 30cm approx. b) calibre required: approximately 7FrC) lumen: 16G/18G/18G; the calibres of the lumens must be declared in the technical data sheet "ANNUAL NEED 1780 "VENOSE CATEGORIES for central cannulation in THREE PLACES TO HIGH FLUXY")length of the catheter 20 cm approx. b) diam. CH12C)lumen: 16G/12G/12G The lumen gauges must be declared in the technical data sheet "ANNUAL NEED 115 "VENOSI CATHETERS for central cannulation with THREE PLACES with antimicrobial treatment based on chlorhexidine/sulfadiazine silver on the outer surface of the catheter) length of the catheter cm 20b) caliber required: 16G /18G/18G Lumen gauges must be declared in the technical data sheet "ANNUAL NEED 625 "VENOSE CATHETERS for central cannulation at FIVE PLACES) catheter length 15cm - 20cm circab) diameter 12 CHc) lumen: 16G/18G/18G/18G/18G/12G Lumen gauges must be declared in the technical data sheet "ANNUAL NEEDS 90 CATHETERS in transparent silicone, with closed and rounded tungsten tip, with valve at the end to prevent blood returns, Tungsten tip closed and rounded Strip and radiopaque tip, atraumatic, Markers polyester cap centimetres, internal rigid stylet, removable, sterile disposable. With Kit for percutaneous introduction peel-away - ch 7 - ch 8 Length cm 50 ANNUAL NEED 110 CATHETERS in transparent silicone, with tungsten tip closed and rounded, with valve at the end to prevent blood returns, Tungsten tip closed and rounded, strip and tip radiopaque, atraumatic, polyester cap.Centimetre markers, internal rigid stiletto, removable, sterile disposable With kit for percutaneous introduction peel-away CH8 length cm 60FABBISOGNO ANNUALE 50 CATETERI VENOSI CENTRALI AD INSERIMENTO PERIFERICO TIPO PICC A PUNTA APERTA WITH KIT FOR INTRODUCTION PERCUTANEA MONOLUME11.1) Catheter caliber 4 Fr WITH MICROINTRODUCTOR annual requirement 40011.2) Catheter caliber 5 Fr annual requirement 220 SPECIFIC FEATURES Single-tube catheter radiopaque centimetre made of polyurethane or other biocompatible material, biostabile and not thrombogenic, equipped with dacron cap - Length 55-60 cm. Suitable for injecting high pressure (300 psi) radiological contrast media. Resistant to KinKing and breakage with conical diameter transition in the distal part of the catheter.Percutaneous introduction kit, also acceptable as a separate kit, containing: a) valve adapter with lateral irrigation port, valve for access without positive pressure needle, introducer needle with a safety system that automatically covers 21 ga ecogenic, a 10 cm peel away introducer, a 0.018 x 70 cm nitinol guide thread with ecogenic tip, malleable metal tunnels, 1 miniature scalpel, 1 fixing fin, 1 10 ml syringe, 1 paper meter.The fastening system must have a subcutaneous chamfered nitinol anchor pin compatible with any lumen adaptable to catheters with external diameter from 5 F to 7 Fr.FABBISOGNO ANNUALE 230 CARATTERISTICHE GENERALI Catheter bilume centimetrato radiopaco in polyurethane or other biocompatible material, biostabile and not thrombogenic, equipped with dacron cap - Length 55-60 cm. Suitable for injecting high pressure (300 psi) radiological contrast media. Resistant to KinKing and breakage with conical diameter transition in the distal part of the catheter.Percutaneous introduction kit, also acceptable as a separate kit, containing: a) valve adapter with lateral irrigation port, valve for access without positive pressure needle, introducer needle with a safety system that automatically covers 21 ga ecogenic, a 10 cm peel away introducer, a 0.018 x 70 cm nitinol guide thread with ecogenic tip, malleable metal tunnels, 1 miniature scalpel, 1 fixing fin, 1 10 ml syringe, 1 paper meter.The fixation system must have a subcutaneous anchorage pin chamfered in nitinol compatible with any lumen adaptable to catheters with external diameter from 3 F to 7 Fr.ANNUAL NEED 295 GENERAL FEATURES - Monolume catheter in biocompatible radiopaque polyurethane with proximal connector with anti-reflux valve, biostable and not thrombogenic - Length 55-60 cm or more, resistant to high pressure infusion (300 psi) with guaranteed flow of 5 ml/sec at 37o for all radiological contrast media from intravenous infusion - Kit for percutaneous introduction, also acceptable separate kit, containing: a)central venous catheter with peripheral insertion, complete with micro-introduction procedural kit, peel away, 21 g introducer needle, 7 cm with safety system, 0.018 i 35 cm guide, needless cap, scalpel and polycarbonate anchoring system composed of 2 sliding pins for the catheter fins and 2 interlocking clamps, with proximal valves inside the luer lock connector that allow the management of the catheter with saline solution, in single lumen configuration and with tip detection method with intracavitary ECG and integrated navigation system, needle for micropuncture of 21 0 22 G caliber ecogenic; (c) peel away introducer of appropriate length and calibre, G20 cannula needle with safety system that automatically covers the needle; (d) connector for access without needle with luer connections; other possible components (scalpels of adequate calibre, grazes, cloths, syringes, masks, dressing and probe covers) with proximal valves inside the luer lock connector that allow the management of the catheter with physiological solution and with the possibility of controlling the tip of the catheter by magnetic navigation. The company will provide free of charge ECG signal detection device and dedicated disposable cable - 4 fr calibre - 5 fr calibre -monolume lumen 18GFABBISOGNO ANNUALE 1302 "Central venous catheters implantable from the periphery (PICC) with double possibility of distal cutting of the catheter and proximal cuttingTechnical features: It is required Picc with polyurethane catheter, with removable fin that allows the cutting of the catheter both at the distal level and possibly proximal to the end of the implant. Device for needleless access (without needle) to neutral flush needle safety Ecogenic, micro-introducer sheath openable, nitinol guide anti-kinking System for documenting seat catheter based on morphology variations waves E.C.G.Grip-lok "FABBISOGNO ANNUALE 80 Central venous catheter in open-pointed polyurethane that can be inserted by peripheral means (PICC), with removable fitting and fixing fins and a Micro Seldinger type micro-introducer, for introduction, removable of its proximal fitting with fixing fins allowing the cutting of the catheter at the proximal level at the end of the implant, complete with procedural kit with method of detection of the tip with intracavitary ECG with its electronic device for monitoring the intraprocedural implant.ANNUAL NEED 510 Catheter in polyurethane monolumen-billumen - trilume coated with chlorhexidine diacetate on both the outer and inner surfaces, radio-opaque injectable technology, centimeter, soft tip with internal mandrel pre-mounted for ECG control, with peel-away introductions, with Nitinol guide. In KIt version fullFABBISOGNO ANNUALE 400 General characteristics - THE SAME OF BATCH 14Specific characteristics calibre 5 FR - calibre 6 FR lumi 18 G/18 GFABBISOGNO ANNUALE 335 General characteristics - THE SAME OF BATCH 14Specific characteristics calibre 6 FR - calibre 6 FR lumi 19 G/17 G/19GFABBISOGNO ANNUALE 85 PORT VENOSI A BASSO PROFILO, WITH PERCUTANEOUS INTRODUCTION KIT AND RELATED INFUSION SETS20.1) totally plastic port (in order not to interfere with any radiotherapy or RNM) with resistant infusion set TAC FABBISOGNO ANNUALE 20220.2) Port with titanium chamber, in non-magnetic material with resistant infusion set TAC YEARLY NEED 212 GENERAL FEATURES Single-centimetre catheter in polyurethane or other biocompatible material, biostabile with fixing fins, length about 20 cm Percutaneous introduction kit, also acceptable as a separate kit, containing: a) micro-stitch needle; b) guide wire minimum length 35 cm made of flexible material, without memory; c) peel away introducer of adequate length and calibre; d) fastening system; e) access cap without needle); other components (scalpel of appropriate calibre, if any). It must allow the short-term administration of pharmacological therapies and hemoderivatives, with a valve such as to screw blood returnsSterile, disposable, in single pack - CALIBER 3 fr -caliber 4 fr - caliber 5 frFABBISOGNO ANNUALE 680 22.1) "GENERAL FEATURES Neonatal catheter in polyurethane to be used for total parenteral nutrition and the administration of drugs intravenously in preterm infants weighing less than 1 kg. Specific characteristicsExtremely small external diameter (1 Fr - 0.33 mm) G28,Length 20 cm Distal marking of the tip and centimetre along the entire length of the tube, integrated polyurethane extension (8 cm). With 24G cannula needle, introducer and mandrel YEARLY NEED 37022.2) AS OVER 30 CM LENGTH YEARLY NEED 50" "PE arterial catheter indicated for haemogas-analysis and blood pressure measurement. It is characterized by a [input]introduction needle with closed-circuit display chamber .Needle with anti-reflux valve,Needle with chamber to display the pulsatile movement of the blood to confirm the arterial puncturePolyethylene catheter for accurate signal transmission. Center cone to facilitate the introduction of the guide "FABBISOGNO ANNUALE 255 "Kit consisting of a PE catheter, with thin-walled introducer needle and semi-transparent needle cone, steel guide thread, soft or helical point, equipped with fixing system, disposable connector."24.1) Fr3 -catheter length 4 cm approx. FABBISOGNO ANNUALE 16024.2) Fr3 -catheter length 6 cm approx. FABBISOGNO ANNUALE 16024.3) Fr3 -catheter length 8 cm approx. FABBISOGNO ANNUALE 160 Kit consisting of catheter (PUR), introducer needle, straight guide (length 20 cm), transparent guide centering device, female luer fitting. Disposable, SterileFr3 -catheter length approx. 6 cm Annual need 220 GENERAL CHARACTERISTICS Catheters used for invasive blood pressure monitoring, without memory, must allow the correct reading of the pressure curve, must be supplied in a set containing: catheter equipped with a fixation device for long-term care; b) introducer needle; c) guide wire for the Seldinger technique; d) sterile, disposable, in a single package.Catheter gauge G18 to G22 . Length 80 mmNUAL NEED 760 27.1) Catheters for cannulation of neonatal arteries and umbilical veins in polyurethane, radiopaque with notches for marking from 6-8 cm depth, with blunt tips open at the distal ends, sterile, apyrogenic and individually packaged with double casing, about connection in rigid die-cast material to the universal graft. Disposable Latex free. In the single lumen, bilume and trilume versions - CH 3,5- CH 5- Length 40 cm NEARNAL FACTORY 47027.2) GENERAL FEATURES Catheters for cannulation of neonatal arteries and umbilical veins in polyurethane, radiopaque with notches for marking from 6-8 cm depth, with rounded tips open at the distal extremities, sterile, apyrogenic and individually packaged with double casing, about connection in rigid die-cast material to the with universal graft. Disposable Latex free. In the single lumen, bilume and trilume versions - CH 2,5 - ANNUAL NEED 60 It must be made of steel, have excellent resistance to traction and tension in order to minimize the risk during the positioning and changing of the catheter, it must penetrate easily without deforming. ANNUAL NEED 60 Kit for bloody monitoring of blood pressure and/or venous integrated with a system to prevent entrapment of air bubbles and closed anti-pollution blood sampling system for single use in sterile packaging, preferably with retro-calibration. The company must supply free of charge cables and supports for transducers necessary for departments.29.1) two-way with no. 1 transducers FABBISOGNO ANNUALE 35029.1) three-way with no. 2 transducers FABBISOGNO ANNUALE 110 "System for fixing to the arm for pressure transducers in soft and comfortable material with elastic velcro closure; provided with at least 3 supports identifiable with color code.FABBISOGNO ANNUALE 550

Opportunity closing date
21 May 2019
Value of contract
£1m-5m

About the buyer

Address
Azienda Sanitaria Locale Salerno Via Nizza 146 Salerno 84124 Italy
Contact
v.mazziotti@aslsalerno.it

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?