Poland - Medical devices

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
23 December 2019
Opportunity publication date
22 November 2019
Category
33100000: Medical equipments
Value of contract
to be confirmed
Your guide to exporting
Report opportunity

Description

ATTENTION DUE TO THE LIMITED NUMBER OF SIGNS, NOT ALL TECHNICAL AND OPERATIONAL VALUES REQUIRED BY THE ORDERING PARTY HAVE BEEN INCLUDED IN THE ANNOUNCEMENT, DETAILS IN THE APPENDIX TO THIS PUBLICATION ARE GIVEN IN THE APPENDIX. 1AEEG 42-channel EEG support 42-channel 1 set Technical and operational values required by the user: see below. Parameters required Limit parameters Offered parameters (specify, describe)Describe in detail each offered parameter1. Test registration station with the function of evaluation and analysis of EEG2 records. Factory new apparatus - required year of manufacture: 2019 Tak3. TECHNICAL PARAMETERS OF THE HEADS Yes4. 42-channel electrode head with amplifiers, analogue-to-digital conversion and galvanic isolation, supplied from Tak5. Number of input channels working in the reference system min.32 Yes6. Number of input printing channels min. 8 Yes7. Min. 1 input SpO2 Yes8. Min. 1 EVENT input Yes9. The head has a system of standard reference electrodes (R) in minimum quantity of 12 Yes10. The head is equipped with an additional active system of two G1/G2 reference electrodes preventing excessive interference of the recorded signal Yes11. Connection of the head to a computer via Ethernet interface using TCP/IP protocol Yes12. Possibility of using printing channels as channels for recording EEG Yes13 signals. Automatic calibration of the head independently at each input of the amplifier Yes14. Possibility of connecting electrodes to the head by means of standard TP DIN 42802 inputs or built-in multi-connector Tak15. Manual selection of impedance measurement by means of a built-in button on the head Yes16. Signalling the impedance level for each electrode by built-in LEDs on the head, which reflect the circuit according to the 10-20 Tak17 standard. Signalling of EEG channel impedance measurement by means of min. 5-degree scale displayed directly on the head Yes18. Signalling of impedance measurement of printing channels by means of min. 5-degree scale displayed directly on the head Yes19. Digital resolution of the A/D converter min. 16bit Yes20. Built-in 50/60 Hz mains filter Yes21. Channel parameters of the head Yes22. Input noise (μV pp) (1-70 Hz) Yes23. Input impedance min. 100(MOhm) Yes24. CMRRR- at the standard input of the reference electrode min. 120dB- at additional input of active electrode system G1/G2 min. 140dB Yes25. SIGNAL REGISTRATION SOFTWARE PARAMETERS Yes26. Time constant (0,03-10) (s) Yes27. Time constant - default value 0,3 (s) Yes28. Sensitivity (10 μV/cm - 2 mV/cm) Yes 29. Sampling rate min. 2000(Hz) Yes30. Unlimited number of renovations defined by the User Yes31. Prefabricated assemblies and programs for standards 10-20, 10-10, 10-10h, 10-5, 5-5 Yes32. Predefined database of medical events containing min. 400 ready-made events. Yes33 Medical events divided into types of events e.g. technical events, physiological events and stimulation events Yes34 Possibility to define, edit and add to the database your own medical events Yes35 Medical event manager allowing to personalize event markers according to your needs Yes36 Possibility to add an interactive note to be examined during signal acquisition Yes37 Min. 3 algorithms for optimizing the display of the EEG curve Customize...ANNEX No. 88 (ANNEX No. 1A) Parameters marked "yes" are limit parameters, which if not fulfilled will result in rejection of the offer. No description will be treated as a lack of the parameter in the offered configuration of the subject of the contract.we declare that the sets offered above are complete and will be ready to use without any additional purchases.the offer should be accompanied by manufacturer's materials in Polish language confirming the fulfillment of the above mentioned parameters.failure to meet any of the limit parameters will result in rejection of the offer. ATTENTION DUE TO THE LIMITED NUMBER OF SIGNS, NOT ALL TECHNICAL AND OPERATIONAL VALUES REQUIRED BY THE ORDERING PARTY HAVE BEEN INCLUDED IN THE ANNOUNCEMENT, DETAILS IN THE APPENDIX TO THIS PUBLICATION ARE GIVEN IN THE APPENDIX. 1BTechnical and operational values required by the user:Lp. Parameters required Limit parameters Offered parameters (specify, describe)Describe in detail each offered parameter General data of the camera1. Apartment brand new from 2019. Yes, two. Recording of 12 ECG leads: presentation of 3, 6 and 12 channels. Yeah, three. Recording speed 5, 10, 25, 50 mm/s. Yeah, four. ECG back recording up to 30 seconds. Yeah, five. 2 operating modes: automatic and manual Yes6. Easy-to-use, intuitive operation allows the ECG to work on a functional alphanumeric keypad. Yeah, seven. LCD colour display min.7" with touch panel Yes8. Recording and printing on paper with a width of min. 112 mm with automatic description of registration parameters, date and time of testing Yes9. Simultaneous display of 12 ECG curves with the possibility to set the parameters of the waveform: speed, sensitivity and print intensity Yes10. Wireless and wired LAN or Internet (WI-FI) communication Yes11. Possibility to perform up to 130 automatic tests on battery operation Yes12. Possibility to work both with power supply directly from the mains and from the built-in battery Yes13. Possibility of receiving orders for testing and sending back the results in HL7 standard via the Internet Yes14. At least three USB ports. Possibility of archiving research for a given period of time on an external carrier. (USB stick) Yes15. Automatic detection of P, QRS, T, and amplitude measurement of all refractions. Measurement of intervals R-R, P-Q, Q-T, and duration of P and QRS. Measurement of the ST segment slope level. Yeah, 16. Continuous heart rate (HR) measurement and display Yes17. Recording gain adjustment: 2.5, 5, 10, 20 mm/mV. Yeah, 18. Print sensitivity min. 2.5; 5; 10; 20 mm/mV Yes19. Digital interference suppression 50 or 60 Hz Yes20. Sampling frequency: 8,000 Hz per channel Yes21. Signaling no contact between electrodes and patient Yes22. Cardiac pacemaker detection Yes23. Memory min. 1,000 studies Yes24. Extension of the device with additional functions - possibility to perform a spirometry screening test Yes25. Menu in Polish Yes26. Trolley for safe ergonomic attachment and mobility of the camera with the possibility of wheel lock, equipped with at least one container for accessories Yes27. Warranty period in months (requiredMin. 24 months) with free overhauls min. 1/year Yes28. Time of starting the repair by the service service max 48hOd of the moment of notification (working days) Yes29. Damage waiting time in days (up to 7 working days) Yes30. Number of repairs giving entitlement to replacement of equipment with new ones (3 repairs of the same component) Yes31. Service in Poland Yes32. Availability of spare parts after the cessation of production of the offered model (minimum) 10 years Yes33. Free service training for medical staff Yes34. Technical documentation of the device allowing to market and use in Poland (CE certificates, declarations of conformity) delivery with the device. Yeah, 35. User manual in Polish Yes36. Service manual and free service training confirmed by a certificate (carried out in the customer's seat) TakParameters marked "yes" are limit parameters, the failure to meet which will result in rejection of the offer.no description will be treated as a lack of a given parameter in the offered configuration of the subject of the contract.we declare that the sets offered above are complete and will be ready to use without any additional purchases.the offer should be accompanied by manufacturer's materials in Polish confirming the fulfillment of the above parameters.failure to meet any of the limit parameters will result in rejection of the offer. ATTENTION DUE TO THE LIMITED NUMBER OF SIGNS, NOT ALL TECHNICAL AND OPERATIONAL VALUES REQUIRED BY THE ORDERING PARTY HAVE BEEN INCLUDED IN THE ANNOUNCEMENT, DETAILS IN THE APPENDIX TO THIS PUBLICATION ARE GIVEN IN THE APPENDIX. 1COnly technical and operational values required by the user: Lp. Parameters required Limit parameters Offered parameters (specify, describe)Describe in detail each offered parameter General data of the camera1. Possibility to perform heparin CVVHD, CVVH, CVVHDF treatments with pre- or postdylation Yes2. Possibility to perform citrate CVVHD, CVVHDF treatments with postdylation Tak3. Possibility of multiple replacement of citrate anticoagulation with heparin anticoagulation during the procedure Yes4. Cassette drainage system allowing easy and quick installation and multiple replacement of the filter during the procedure, without the need to replace the entire cassette Yes5. Integrated citrate and calcium drains with extracorporeal circulatory system Yes6. Uninterrupted supply of citrate during changing bags of dialysate, substitute, filtrate Yes7. Possibility to collect dialysate solution from 4 bags without additional connection Yes8. Possibility to connect a bag/bags for filtrate up to 20 L Yes9. Possibility to change and save default parameters for each type of treatment Yes10. Substitute flow range 10 - 160 ml/min. Yeah, 11. Dialyzate/substitute temperature control range 35 - 39 oC Yes12. Possibility to switch off heating of solutions Yes13. Adjustable ultrafiltration 0 - 990 ml/hour Yes14. Blood pump capacity 10 - 500 ml/min Yes15. Integrated rotating hemofilter handle Yes16. Communication via 15" touch screen Yes17. Screen can be set in 3 planes Yes18. Context-sensitive aid scheme Yes19. Adjustable blood level in the venous lake from the level of the screen Yes20. Two air detectors Yes21. 6 peristaltic pumps integrated in the front panel Yes22. Additional syringe pump with automatic detection of 30/50 ml syringe connection Yes23. Pressure measurement of arterial, venous and before filter without contact with air Yes24. Possibility to obtain retrograde blood flow without disconnecting the cardiovascular system and rinsing the catheter Yes25. Graphical color preview of important operating states of the device Yes26. Emergency power supply ensuring the maintenance of the extracorporeal circulation for at least 15 min. Yes27. Two individual heating systems integrated in the housing Yes28. Independent ventilation of substitute drains, dialysate or filtrate Yes29. Gravity balancing system with four independent balances Yes30. Accuracy of weighing on every scale: 1 g Yes31. Possibility to switch to "care mode" during the treatment with the balancing off and reduced blood flow Yes32. Camera trolley with 4 independent wheels, 2 of them with two-stage lock Yes33. Two handles at the front and back of the camera for easy movement/rotation of the Tak34. Blood leak detector Tak35. Warranty period in months (requiredMin. 24 months) with free overhauls min. 1/year Yes36. Software in Polish with a free software update during the whole period of exploitation.37. Time of starting the repair by the service max 48hOd the moment of notification (working days) Yes38. Damage waiting time in days (up to 7 working days) Yes39. Number of repairs giving entitlement to replacement of equipment with new ones (3 repairs of the same component) Yes40. Service in Poland Yes41. Availability of spare parts after the cessation of production of the offered model (minimum) 10 years Yes42. Free service training for medical staff Yes43. Technical documentation of the device allowing to market and use in Poland (CE certificates, declarations of conformity) delivery with the device. Yes, 44. User manual in Polish Yes45. Service manual and free of charge.......................................................................................................................................................................................................................................... TO THE CCI. NOTE: DUE TO THE LIMITED NUMBER OF SIGNS, THE ANNOUNCEMENT DOES NOT INCLUDE ALL THE TECHNICAL AND OPERATIONAL VALUES REQUIRED BY THE ORDERING PARTY, DETAILS ARE PROVIDED IN THE APPENDIX. 1DLp. Parameters required Limit parameters Offered parameters (specify, describe)Describe in detail each offered parameter1. Year of manufacture 2019 Yes2. Portable monitoring device without the need for an additional screen or laptop to facilitate work weighing no more than 7 kg Yes3. Continuous impedance measurement to verify adequate contact with tissue Yes4. Device having min. 4 differential channels (min. 8 inputs) Yes5. Expandable with a module for measuring somatosensory evoked potentials (SEP) and a module for stimulation and measurement of the autonomic nervous system in pelvic surgery Yes6. Imaging of slow running and evoked EMG potentials Yes7. Recording of EMG-call potentials in the report by footswitch or by pushbutton on the unit Yes8. Two integrated direct current stimulators with the following ranges: min. current 1-25mA, frequency 1-30Hz, pulse length 50-1000μs, voltage min. 100V for direct and continuous nerve stimulation Yes9. Two-phase cortical and subcortical stimulation. Reception of MEPs from the muscles Yes10. TOF measurement to check patient relaxation Yes11. The camera is equipped with a color LCD screen min. 8''' and EMG response sound signal with choice of signal type Yes12. EMG-call response sound Yes13. Dedicated sounds (tones) for each EMG channel (min. 4 channel monitoring); spontaneous EMG response detection Yes14. Operating menu in Polish Yes15. Entering patient data into the internal memory of the instrument manually or using a barcode scanner Yes16. Connecting reusable and disposable accessories to the camera Yes17. Intuitive operation of the camera by means of buttons and function knobs or the supplied alphanumeric keypad Yes18. Camera with internal memory min. 1000 patient data records with stored EMG curves and the ability to read the stored record at any time after surgery Yes19. Print treatment report to PDF file Yes20. Connecting accessories to the patient in a permanent and safe way Yes21. Additional function interfaces: USB - min. 3 pcs., Ethernet - min. 1pcs, VGA min. 1pcs. Yeah, 22. Hospital network operation via Ethernet port Yes23. Connection cable to the electrode glued to the endotracheal tube 1 pc. Yeah, 24. EMG interface in the number of channels according to the offered system, cable length min. 4m, yes 25. RF artifact suppression sensor, cable length min. 4m Yes26. Disposable earthing electrode, green, needle length min. 20mm, cable length min.3m - 5 pieces Yes27. Multi-coloured pairs of disposable needle-shaped electrodes, interlaced wire, needle length min. 15mm, cable length min. 2m - 20 pieces Yes28. Set of disposable triple needle electrodes, interlaced wire, for 2-channel EMG monitoring of needle length min. 15mm and earthing electrode green needle length min. 15mm, cable length min. 1.5m - set of 5 sets Yes29. A set of disposable needle-shaped electrodes for spine treatment, multicolour pairs, needle length min. 20mm, cable length min. 2m. - 1 set Yes30. Receive electrode for single use, glued fully onto a minimum size endotracheal tube. 7-9, active surface evenly distributed over the entire circumference of the tube at the point of contact with the vocal folds, min. 4 receiver channels with neutral electrode - 3 pieces Yes31. Receive electrode for single use, glued fully onto a minimum size endotracheal tube. 7-9, active surface evenly distributed over the entire circumference of the tube at the point of contact with the vocal folds, min. 4 channels with neutral electrode - 3 channels Yes32. One-time probes..... TO THE CCI. 52 NOTE: DUE TO THE LIMITED NUMBER OF SIGNS, NOT ALL TECHNICAL AND OPERATIONAL VALUES REQUIRED BY THE ORDERING PARTY HAVE BEEN INCLUDED IN THE ANNOUNCEMENT, DETAILS IN THE APPENDIX TO THIS PUBLICATION ARE GIVEN IN THE APPENDIX. 1EOperative technical properties required by the user: No. Parameters required Limit parameters Offered parameters (specify, describe)Describe in detail each offered parameter1. Control console of the hysteroscope shaver Tak2. Control console for the hysteroscope shaver handle equipped with: - numeric and bar display informing about the current speed of the shaver blade, - numeric display informing about the maximum speed of the shaver blade adjustable to Tak3. The console is equipped with a socket enabling direct connection with the offered suction and flushing pump and synchronized operation (activation of the shaver and suction by means of one footswitch) Yes4. The function of setting the speed of the shaver blade by means of buttons on the console panel in the range of min. 500 - 5000 rpm Yes5. Activation of the shaver and the pump by means of the one pedal footswitch, two-stage: - first stage - activation of the suction pump only, - second stage - activation of the oscillation of the shaver blade Yes6. Possibility of connecting a laparoscopic morcelator with automatic recognition function to the control console and setting a dedicated speed range. Yeah, seven. Instrumentarium for hysteroscopic shaver Yes8. Optics with axial working channel for intrauterine operations, wide viewing angle, viewing angle 6°, length 20 cm, diameter 19 Fr., autoclavable, equipped with: - parallel eyepiece,- Hopkins roller lens system,- working channel compatible with blades of hysteroscopic shaver with diameter 4 mm; working channel input equipped with seal and removable faucet,- separate LUER-Lock connection for flushing connection,- fiber optic connection equipped with min. 3 adapters for fiber optic cables of different manufacturers - 1 pc. Yes, nine. Compatible obturator - 1 pc. Yeah, 10. Shaver handle compatible with control console - 1 set Yes11. The construction of the shaver handle provides different ways of holding, i.e. simple and pistol grip Yes12. The pistol grip is provided by the optional detachable handle, which can be mounted in various positions. Integrated in the central handle (on the blade axis extension), straight suction channel for evacuation of excised tissue fragments Yes14. Hysteroscopic shaver blade, straight, autoclavable, concave cutting window, serrated cutting edges, diameter 4 mm, length 32 cm - 1 pc. Yeah, 15. Hysteroscopic shaver blade, straight, autoclavable, rectangular cutting window, serrated cutting edges, diameter 4 mm, length 32 cm -1 pcs. Yeah, 16. Cleaning adapter with LUER-Lock connector, for cleaning of Shaver blades - 1 pc. Yeah, 17. Cleaning adapter with LUER-Lock connector, for cleaning the Shaver holder - 1 pc. Yeah, 18. Coagulation electrode, bipolar - 1 pc. Yeah, 19. Bipolar wire, length 300 cm - 1 pc. Yeah, 20. Gripping and preparation pliers, diameter 4 mm, length 36 cm, - 1 pc. Yeah, 21. Preparation pliers, diameter 4 mm, length 36 cm, - 1 pc. Yeah, 22. Scissors, diameter 4 mm, length 36 cm, - 1 pc. Yeah, 23. Perforated plastic container for sterilization and storage of instruments, two-level, external dimension min. 520x240x115mm, set consisting of: Container, Cover, Silicone mat, Fixing clips (24pcs), Silicone straps (24pcs) - 1 set. Yeah, 24. Suction pump - 1 set Yes25. Pump to be used during intrauterine operations using the Tak26 hysteroscope shaver. Pump equipped with a dedicated program to work with a hysteroscope shaver Yes27. Pump equipped with a socket for direct connection to the shaver console and synchronized operation (activation of the shaver and suction by means of one footswitch) Yes28. Pump design for extended range of applications. TO THE CCI. NOTE: DUE TO THE LIMITED NUMBER OF SIGNS, THE ANNOUNCEMENT DOES NOT INCLUDE ALL THE TECHNICAL AND OPERATIONAL VALUES REQUIRED BY THE ORDERING PARTY, DETAILS ARE PROVIDED IN THE APPENDIX. 1FTechnical and operational values required by the user: No. Parameters required Limit parameters Offered parameters (specify, describe)Describe in detail each offered parameter General data of the camera1. Factory new device Tak2. Power supply: 220 - 230 VAC 50/60 HZ Yes3. High frequency electric pulse generator designed for thermolesion, disc decompression, regeneration, multi-electrode-palisade lesion, epidural neurostimulation Yes4. The camera is equipped with a touch screen LCD screen with a diagonal of min. 12" with anti-glare coating and backlight, 2 user interface options: digital and graphic, manual control by the operator with a knob, footswitch Yes5. START/STOP button on the generator's desktop, which allows you to turn on/stop the funnel at any time without having to turn off the device Yes6. Possibility to perform sleep in 4 points simultaneously with separate connection of 4 electrodes in the device Yes7. Screen display of voltage, current, temperature, time and power values for each of the electrodes used separately Yes8. Thermal insulation in modes:- Continuous - Pulsed Yes9. Possibility to perform monopolar and bipolar lesions Yes10. Temperature measurement range at the end of the electrode: 0 - 110oC Yes11. STYMULATION Yes12. Motor pulses: 2.5 Hz Yes13. Sensory pulses: 2, 5, 50, 75, 100, 150, 180 and 200 Hz Yes14. Blood pump capacity 10 - 500 ml/min Yes15. Pulse width 0.1, 0.5, 1, 2 and 3ms Yes16. Output voltage regulation for sensory and motor stimulation: 0 - 3V Yes17. Selection of the type of stimulation manual and automatic: suggests the frequency of impulses for the selected stimulation and the correct voltage range Yes18. Continuous Thermolysis Yes19. Automatic RF power control, which does not allow to exceed the set temperature value from the range of min. 37 to 95oC. Adjustment with the accuracy of 1oC Yes20. Time adjustable in the range of min: 5 seconds to 30 minutes. Adjustment with the accuracy of 1s. Yeah, 21. Output power per active electrode socket: 0 - 50 W Tak22. Possibility of programming temperature rise profiles Yes23. You can program your own profiles. Yeah, 24. Profile programming:- Possibility of setting the initial temperature (temperature before the first temperature increase)- Duration of temperature - Temperature increase (value by which the temperature will increase between successive steps)- End time (time the generator should maintain at the set final temperature)- End value of temperature Yes25. Frequency - 480 kHz, sinusoidal wave Yes26. Simultaneous display of the values on the touch screen LCD:- Voltage: 0 - 100V for impedance from 30 to 3000Ω- Current: 0 - 700 mA- Time: 5 sec- 30 min- Temperature: 37 - 95 oC- Power: 0 - 50 W Yes27. Acoustic signal at the end of the lesion Yes28. Lazy control in automatic mode Yes29. Manual operation of lesions Yes30. PULSE THERMOLESSION Yes31. Adjustable time: from 5 s to 30 min Yes32. Pulse width adjustable: from 2 to 30 ms, in 1 ms steps Yes33. Adjustable frequency: 1, 2, 3, 4, 5, 6, 7, 8, 9 and 10 Hz Yes34. Adjustable voltage: from 0 to 100 V Yes35. Permissible regulated temperature: from 37 to 95oC with an accuracy of 1oC Yes36. Automatic control of the set temperature Yes37. Acoustic signal at the end of the lesion Yes38. OTHER FEATURES Yes39. Possibility of thermoelesion - epidural neuromostimulation based on a single use of a monopolar epidural electrode with temperature control and reading and a port for injection Yes40. Cross-hip joint lesions based on the use of 4 electrodes (bipolar) Yes41. The ability to perform with... TO THE CCI. 72 NOTE: DUE TO THE LIMITED NUMBER OF SIGNS, NOT ALL TECHNICAL AND OPERATIONAL VALUES REQUIRED BY THE ORDERING PARTY HAVE BEEN INCLUDED IN THE ANNOUNCEMENT, DETAILS IN THE APPENDIX. 1GWORKS Technical and operational values required by the user:Lp. Parameters required Limit parameters Offered parameters (specify, describe)Describe in detail each offered parameter1. Parameters General2. Factory new apparatus - required year of manufacture: 2019 Yes/number3. Frequency range min. 2.0 - 17.0 MHz Yes/no 4. Number of processing channels min. 1 000 000 Yes - specify5 Number of independent electronically switched sockets min. 4 Yes6. High-resolution monitor with min. 21" Yes - specify7. Monitor position can be adjusted independently of the control panel. Yeah, eight. Adjustable control panel position +/- 90 degrees Yes9. Possibility of recording and playing back dynamic images (so called Cine loop) Yes10. An integrated hard disk image archiving system that can be exported to DVD/CD removable media. Data and image transmission in computer network according to DICOM 3.0 standard (Dicom Storage, Print, Worklist) + integration with existing PACS system Yes - enter12. Possibility of password protection for data access. Yeah, 13. Control panel with height adjustment min. 10cm Yes14. Integrated HDD min. 500GB Yes - enter 15. Touch screen for operating the camera with min. 13" Yes16. Touch panel tilt adjustment Yes - specify17. Alphanumeric keypad pulls out from the control panel. Yeah, 18. Dedicated built-in gel heater. Yeah, 19. Thermal printer (video) black and white Yes - specify20. 2D mode (B-mode) Yes21. Setting range of penetration depth min. 1-30cm Yes - specify22. Lossless zoom range of the actual image min. 8x Yes23. Dynamic range of the system min. 300 [dB] Yes - specify24. Application of compounding technology with the possibility of selecting at least 7 directions of control of image lines. Yes - enter 25. Application of automatic image optimization technology in B mode and pulsed Doppler parameters at the touch of a button. Yeah, 26. M mode Yes27. Anatomical mode M Yes - specify28 Spectral mode Pulse Doppler (PWD) Yes29. Maximum measured flow velocity [cm/s] at 0 correction angle min. Doppler gate size min. 0.5 to 20 mm Yes - specify31. Doppler gate angle correction angle min. 80 Yes - specify32. Doppler mode Color (CD) Yes33. Colour Doppler field tilt adjustment Yes - specify34. Angiological mode (power Doppler) Yes35. Power Doppler (Power Doppler) directional Yes - specify36. Harmonic imaging Yes -37. Harmonic imaging on all offered heads Yes - specify38. Duplex mode (2D + PWD or CD) Yes -39. Triplex mode (2D + PWD + CD) Yes40. Measuring software with calculation package Yes41. Automatic calculation package for Doppler (automatic spectrum contour) Yes - specify43. Medical station for evaluation of US, CT, MR tests, equipped with a PC, 2 diagnostic monitors with 24' resolution of 2.3 MP Yes - specify44. Linear multifrequency head for vascular tests Yes - specify44. Operating frequency range of the transmitter min. 3.0 - 14.0 MHz Yes - enter46. Number of elements min. 128 Yes - enter47. 38-40 mm Yes - enter48. Trapezoidal imaging Yes - enter49. Possibility of working with a biopsy attachment Yes - enter50. Linear multifrequency head for surface and small organ examination. Yeah, 51. Frequency range of the transmitter operation... TO THE CCI. 83

Opportunity closing date
23 December 2019
Value of contract
to be confirmed

About the buyer

Address
Specjalistyczne Centrum Medyczne im. św. Jana Pawła II S.A. ul. Jana Pawła II 2 Polanica-Zdrój 57-320 Poland
Contact
zp@scm.pl

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?