Germany - Installation of electrical cables

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
21 May 2019
Opportunity publication date
17 April 2019
Category
45310000
Value of contract
to be confirmed
Your guide to exporting
Report opportunity

Description

The measure involves the new use of a wide variety of existing areas on levels -2 and -1. These include rooms used for medical purposes in Group 0, Group 1 and Group 2. These include the following topics: UPS system (approx. 60 kVA), cables and wires for general use Power supply, cables and lines for safety power supply, end distributors, IT network display panels, distributors and accessories, medical equipment distributors, marshalling distributors, switching and consumption devices, milling and drilling work, equipotential bonding, fire protection measures, cable routing aids, connections for equipment provided, smoke extraction systems, overvoltage protection, preparatory measures, testing of power supply systems, documentation, sun protection, Media supply unit, general lighting and light control, lightning protection adaptation, central TC (licences), telephone system (Dect, illumination), language terminals, light call system, door opener systems, clock system, public address system, intercom systems, TV sets, antenna system, fire alarm system, sub-central control unit, fire alarm system installation, BOS radio system, preparation for access control, data network distributor, patient entertainment and high-voltage systems in outdoor areas. Further description: Cables and wires up to a cross-section of 5 x 25 mm2 approx. 80 000 m. Cables and wires up to a cross-section of 4 x 240/120 mm2 approx. 10 000 m. Cables and wires up to a cross-section of 12 x 2 x 0.8 mm approx. 50,000 m. Fibre optic cables up to 24 fibres approx. 3 000 m. For cable distribution, approx. 900 m of routes in various sizes and approx. 7,500 collector holders up to <70 are provided, among other things. Various end distributors and IT network distributors are required for the areas. A new IT network infrastructure for the conversion area is planned. Consisting of approx. 28 new data cabinets and smaller data cabinets for a separate GLT data network. A new fire alarm sub-central control panel with approx. 20 new loops and approx. 700 automatic smoke detectors is available for new use. The existing nurse call system is extended. Approx. 60 rooms will receive a nurse call system. Inventory of various cables and lines including dismantling and coordination (coordination with the client). All work must be approved by the client, as some existing circuits remain in operation. Safety measures for cables and wires in operation before demolition work must be provided. Dismantling of existing roads - approx. 120 m. Sealing of feedthroughs (fire protection) as well as various core drillings are included in the scope of services. 15 % of the output shall be provided in 2019, 35 % in 2020, 45 % in 2021 and 5 % in 2022. The work shall be carried out in several phases. Construction cycle 1 Manufacture 1.3 Storage/waste E-2 Kitchen changing room E-2 Prosektur, changing room E-2 Parts in technical area E-1/E-2 Construction cycle 2 Manufacture 2.1 MVZ E-1 Compressed air system E-1 2.3 Workshop E-2 Construction cycle 3 Demolition 3.1 Married pathology E-1 Married storage/compressed air/wash E-1 Functional diagnostics E-1 Corridor E-1 Compressed air system E-1 Manufacture 3.2 Recovery room and surrounding areas Demolition 3.3 Secondary rooms LHKM Corridor E-1 Manufacture 3.4 Manufacture IVZ Endo Urology/FKTD Construction cycle 4 Demolition 4.1 PHTH Part 1 Manufacture 4.2 PHTH Part 1 Demolition 4.3 PHTH Part 2 Manufacture 4.4 PHTH Part 2.

Opportunity closing date
21 May 2019
Value of contract
to be confirmed

About the buyer

Address
Sana Klinikum Hof GmbH Eppenreuther Str. 9 Hof/Saale 95032 Germany
Contact
matthias.albrecht@sana.de

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?