Germany - Electrical installation work for power distribution systems

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
30 January 2020
Opportunity publication date
17 December 2019
Category
45317300: Electrical installation work of electrical distribution apparatus
Value of contract
£0-100k
Your guide to exporting
Report opportunity

Description

Electrical installation for the new F-Tract and the conversion of the C-Tract:- 18 sub-distributors as stand-alone distributors up to H x W x D 1 950 x 1 050 x 205 mm,- 4 sub-distributors IT network with 6.3kVA transformer,- approx. 300 m cable 4 x 185 mm2 in empty conduit system with threading shafts in outdoor area,- approx. 110 m cable 4 x 185 mm2 on installation systems in the building,- approx. 880 m cable 5 x 25 mm2 on installation systems in the building,- approx. 44 000 m cables and wires from 5 x 16 mm2 to 3 x 1.5 mm2 on installation systems, on raw flooring, in empty conduit system in concrete walls, flush-mounted in masonry in the building,- approx. 33 400 m cables and lines for building automation from 5 x 2.5 mm2 to 3 x 1.5 mm2 and 2 x 2 x 0.8 mm to 4 x 2 x 0.8 mm on installation systems,- approx. 2 065 m cable tray and conductors from 100 mm to 400 mm wide,- approx. 2,800 flush-mounted installation devices such as switches, push-buttons, sockets, presence detectors etc,- approx. 810 lamps, divided into recessed and surface-mounted lamps,- approx. 150 running metres of light strip in partial lengths between 2.8 m and 19 m,- approx. 40 LED escape sign lamps,- 1 equipotential bonding unit with approx. 2 550 m equipotential bonding conductor from 1 x 4 mm2 to 1 x 50 mm2 and approx. 70 equipotential bonding rails,- 1 pc. Lightning protection system with approx. 4 00 m interception cable, approx. 110 m arrestors and approx. 8 interception rods up to 4 m length,- approx. 130 cables and cable bulkhead up to S90 in wall and ceiling,- approx. 170 pcs. Core drillings up to D 125 x L 240 mm in solid wall and ceiling, - approx. 340 pcs. pipe, box and pipe bulkhead system up to F90 in lightweight wall, - dismantling work in existing buildings with approx. 650 m cables and wires up to 5 x 16 mm2, approx. 35 pcs. lights. New Installation of the main energy distribution of the children's hospital Köln-Riehl in the course of the new building F-Trakt- 1 St. Low-voltage main distribution NSHV-AV with 15 fields:-- Field 1; power field < 630 A - for vertical installation of equipment,-- Field 2; power field > 630A - coupling field,-- Field 3; as empty field for retrofitting NH strips vertically,-- Field 4; power field < 630 A - for horizontal installation of equipment,-- Field 5; power field < 630 A - for horizontal installation of equipment,-- Field 6; power field > 630A - field with central earthing point,-- Field 7; corner field,-- Field 8; PowerField > 630A - coupling section, section 9; PowerField > 630A - input/output section 1 switch, section 10; corner section, section 11; power section < 630 A - for horizontal installation of equipment, section 12; Power field < 630 A - for horizontal installation of equipment,-- field 13, load break switch with fuses, circuit breaker 630 A,-- field 14; Power field > 630A - coupling field,-- field 15; Power field < 630 A - for vertical installation of equipment,- 1 pc. Low-voltage main distribution NSHV-SV with 9 fields:-- Field 1; PowerField > 630A - Input/output field 1 Switch,-- Field 2; PowerField > 630A - Input/output field 1 Switch,-- Field 3; PowerField < 630 A - For horizontal installation of equipment,-- Field 4; Cable entry field,-- Field 5; Power field < 630 A - for horizontal installation of equipment,-- field 6; Power field > 630A - coupling field,-- field 7; Power field < 630 A - for horizontal installation of equipment,-- field 8; corner field,-- field 9; Power field < 630 A - for horizontal installation of equipment.- approx. 300 m cable 4 x 185 mm2 in empty conduit system with thread shafts in outdoor installation,- approx. 110 m cable 4 x 185 mm2 on installation systems in building,- approx. 40 m cable 5 x 6 mm2 in empty conduit system with thread shafts in outdoor installation,- approx. 35 m cable 5 x 6 mm2 on installation systems in the building,- approx. 475 m cables and wires from 5 x 2.5 mm2 to 3 x 1.5 mm2 on installation systems in the building,- approx. 230 m cable tray and conductors from 100 mm to 500 mm wide,- approx. 20 pcs. Surface-mounted installation devices such as switches, push-buttons, sockets, presence detectors, junction boxes, etc.,- approx. 4 luminaires as surface-mounted diffuser luminaires,- 1 equipotential bonding unit with approx. 500 m equipotential bonding conductor from 1 x 16 to 1 x 95 mm2 and approx. 5 equipotential bonding rails,- approx. 60 cables and cable bulkhead up to S90 in wall and ceiling,- approx. 50 core bores up to D 125 x L 240 mm in solid wall and ceiling.

Opportunity closing date
30 January 2020
Value of contract
£0-100k

About the buyer

Address
Kliniken der Stadt Köln gGmbH Neufelder Straße 34 Köln 51067 Germany
Contact
kuckertzt@kliniken-koeln.de

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?